S'abonner

A new iPhone application for the measurement of active craniocervical range of motion in patients with nonspecific neck pain: A reliability and validity study - 15/07/18

Doi : 10.1016/j.rehab.2018.05.319 
M.R. Pourahmadi 1, , R. Bagheri 2, M. Taghipour 3, I. Ebrahimi Takamjani 1
1 Iran University of Medical Sciences, Department of Physiotherapy, Tehran, Iran 
2 Semnan University of Medical Sciences, Neuromuscular Rehabilitation Research Center, Department of Physiotherapy, Semnan, Iran 
3 University of Social Welfare and Rehabilitation Sciences, Department of Physiotherapy, Tehran, Iran 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction/Background

Measurement of cervical spine range of motion (ROM) is often considered to be an essential component of cervical spine physiotherapy assessment. This study aimed to investigate the reliability and validity of an iPhone application (app) (Goniometer Pro) for measuring active craniocervical ROM (ACCROM) in patients with nonspecific neck pain.

Material and method

A cross-sectional study was conducted at the musculoskeletal biomechanics laboratory located at Iran University of Medical Sciences. Forty nonspecific neck pain patients participated in this study. The outcome measure was the ACCROM, including flexion, extension, lateral flexion, and rotation. Following the recruitment process, ACCROM was measured using a universal goniometer (UG) and iPhone 7 app. Two blinded examiners each used the UG and iPhone to measure ACCROM in the following sequences: flexion, extension, lateral flexion, and rotation. The second (2hours later) and third (48hours later) sessions were carried out in the same manner as the first session. Intraclass correlation coefficient (ICC) models were used to determine the intra-rater and inter-rater reliability. The Pearson correlation coefficients were used to establish concurrent validity of the iPhone app. Minimum detectable change at the 95% confidence level (MDC95) was also computed.

Results

Good intra-rater and inter-rater reliability was demonstrated for the goniometer with ICC values of ≥ 0.66 and ≥ 0.70 and the iPhone app with ICC values of ≥ 0.62 and ≥ 0.65, respectively. The MDC95 ranged from 2.21° to 12.50° for the intra-rater analysis and from 3.40° to 12.61° for the inter-rater analysis. The concurrent validity between the two instruments was high, with r values of ≥ 0.63. The magnitude of the differences between the UG and iPhone app values (effect sizes) was small, with Cohen d values of ≤ 0.17.

Conclusion

The iPhone app possesses good reliability and high validity. It seems that this app can be used for measuring ACCROM.

Le texte complet de cet article est disponible en PDF.

Keywords : Cervical vertebrae, Range of motion, Smartphone


Plan


© 2018  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 61 - N° S

P. e143 - juillet 2018 Retour au numéro
Article précédent Article précédent
  • Changes in muscle tone and stiffness around shoulder associated with radiotherapy in breast cancer patients
  • S.M. Yeo, S.Y. An, I.Y. Cheong, W. Park, J.H. Hwang
| Article suivant Article suivant
  • Evaluation of suprascapular nerve block and intra-articular steroid injection as a treatment modality in patients with periarthritis shoulder
  • S. Jain, D. Borah, D.S. Meena

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.