S'abonner

Comparison of cementless total hip arthroplasty survivorship between metal-on-highly cross-linked polyethylene and ceramic on ceramic bearings: A case control study with a 5-9-year follow-up - 22/08/18

Doi : 10.1016/j.otsr.2018.04.016 
Yoshitoshi Higuchi , Taisuke Seki, Yukiharu Hasegawa, Daigo Morita, Daigo Komatsu, Yasuhiko Takegami, Naoki Ishiguro
 Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, 65, Tsurumai-cho, 4668550 Showa-ku, Nagoya city, Aichi prefecture, Japan 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Currently, there is a lack of evidence on the medium-term follow-up of cementless total hip arthroplasty (THA) using metal-on-highly cross-linked polyethylene bearing (MoXPE), ceramic on ceramic bearing (CoC) at more than 5 years follow-up. Therefore, we performed a case control study to: compare the incidence rate of osteolysis; compare the longevity for both types of THAs, and to evaluate the wear rate of MoXPE THAs.

Hypothesis

CoC THAs will have a lower rate of osteolysis and better longevity than MoXPE THAs.

Patients and methods

We performed a retrospective analysis of 77 MoXPE (68 women, 9 men) and 105 CoC (85 women, 20 men) THAs, with an average patient age at the time of surgery of 64.7 years (range, 27 to 76 years). The cohorts were matched according to sex, body mass index, or diagnosis of hip joint disease. Clinical and radiologic measurements were analyzed at a mean follow-up of 6.7 years (range, 5–9 years).

Results

There were no between-group differences with regard to the Harris hip score (87.0 [64.0–98.0] and 89.9 [70.0–100.0] for the MoXPE and CoC group, respectively) and the incidence rate of osteolysis (2.6% and 1.9%, respectively). Revision was required for 1 case for each THA type. The Kaplan-Meier survival at 8 years, using implant loosening or revision as the end-point of analysis, was 96.1% (95% confidence interval [CI], 90.0–99.3) for the MoXPE group and 98.9% (95% CI, 92.2–99.8) for the CoC group (p=0.189). The mean annual liner wear rate was 0.0160mm/year (range, 0.0050 to 0.0390mm/year) for the MoXPE THAs.

Discussion

There was no difference between CoC and MoXPE THAs in the incidence of osteolysis or in survival rate at 8 years post-surgery. Excellent clinical and radiological outcomes were obtained for both types of bearings.

Level of evidence

III, Case control study, case control retrospective design.

Le texte complet de cet article est disponible en PDF.

Keywords : Ceramic on ceramic bearing, Metal-on-highly cross-linked polyethylene bearing, Total hip arthroplasty, Wear


Plan


© 2018  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 104 - N° 5

P. 663-669 - septembre 2018 Retour au numéro
Article précédent Article précédent
  • Translation, cross-cultural adaption and validation of the French version of the Forgotten Joint Score in total hip arthroplasty
  • Shahnaz Klouche, Johannes M. Giesinger, El-Hadi Sariali
| Article suivant Article suivant
  • Optimal timing for elective total hip replacement in HIV-positive patients
  • Chun-Hung Chang, Shang-Wen Tsai, Cheng-Fong Chen, Po-Kuei Wu, Wing-Wai Wong, Ming-Chau Chang, Wei-Ming Chen

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.