S'abonner

Characterization of breast lesion using T1-perfusion magnetic resonance imaging: Qualitative vs. quantitative analysis - 19/10/18

Doi : 10.1016/j.diii.2018.05.006 
S. Thakran a, P.K. Gupta b, V. Kabra c, I. Saha d, P. Jain e, R.K. Gupta b, A. Singh a, f,
a Centre for Biomedical Engineering, IIT Delhi, New Delhi, India 
b Department of Radiology and Imaging, Fortis Memorial Research Institute, Gurgaon, India 
c Department of Surgical Oncology, Fortis Memorial Research Institute, Gurgaon, India 
d Philips Healthcare, Philips India Ltd, Gurgaon, India 
e SRL Diagnostics, Fortis Memorial Research Institute, Gurgaon, India 
f Department of Biomedical Engineering, All India Institute of Medical Sciences Delhi, New Delhi, India 

Corresponding author. Centre for Biomedical Engineering, IIT Delhi, Hauz Khas, Block-II, Room No. 299, 110016 New Delhi, India.Centre for Biomedical Engineering, IIT Delhi, Hauz Khas, Block-II, Room No. 299New Delhi110016India

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Objectives

The objective of this study was to quantify the hemodynamic parameters using first pass analysis of T1-perfusion magnetic resonance imaging (MRI) data of human breast and to compare these parameters with the existing tracer kinetic parameters, semi-quantitative and qualitative T1-perfusion analysis in terms of lesion characterization.

Materials and methods

MRI of the breast was performed in 50 women (mean age, 44±11 [SD] years; range: 26–75) years with a total of 15 benign and 35 malignant breast lesions. After pre-processing, T1-perfusion MRI data was analyzed using qualitative approach by two radiologists (visual inspection of the kinetic curve into types I, II or III), semi-quantitative (characterization of kinetic curve types using empirical parameters), generalized-tracer-kinetic-model (tracer kinetic parameters) and first pass analysis (hemodynamic-parameters). Chi-squared test, t-test, one-way analysis-of-variance (ANOVA) using Bonferroni post-hoc test and receiver-operating-characteristic (ROC) curve were used for statistical analysis.

Results

All quantitative parameters except leakage volume (Ve), qualitative (type-I and III) and semi-quantitative curves (type-I and III) provided significant differences (P<0.05) between benign and malignant lesions. Kinetic parameters, particularly volume transfer coefficient (Ktrans) provided a significant difference (P<0.05) between all grades except grade-II vs III. The hemodynamic parameter (relative-leakage-corrected-breast-blood-volume [rBBVcorr) provided a statistically significant difference (P<0.05) between all grades. It also provided highest sensitivity and specificity among all parameters in differentiation between different grades of malignant breast lesions.

Conclusion

Quantitative parameters, particularly rBBVcorr and Ktrans provided similar sensitivity and specificity in differentiating benign from malignant breast lesions for this cohort. Moreover, rBBVcorr provided better differentiation between different grades of malignant breast lesions among all the parameters.

Le texte complet de cet article est disponible en PDF.

Keywords : Magnetic resonance imaging (MRI), Perfusion MR imaging, Breast tumor, Lesion grading, Quantitative and qualitative analysis


Plan


© 2018  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 99 - N° 10

P. 633-642 - octobre 2018 Retour au numéro
Article précédent Article précédent
  • Decreased operator X-ray exposure by optimized fluoroscopy during radiofrequency ablation of common atrial flutter
  • A. Zedira, J. Greffier, X. Brunet, F. Pereira, P.-F. Winum, M. Granier
| Article suivant Article suivant
  • Predicting prognosis of resected hepatocellular carcinoma by radiomics analysis with random survival forest
  • H. Akai, K. Yasaka, A. Kunimatsu, M. Nojima, T. Kokudo, N. Kokudo, K. Hasegawa, O. Abe, K. Ohtomo, S. Kiryu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.