S'abonner

Are dual mobility cups associated with increased metal ions in the blood? Clinical study of nickel and chromium levels with 29 months’ follow-up - 23/11/18

Doi : 10.1016/j.otsr.2018.08.012 
Laura Marie-Hardy , Padhraig O’Laughlin, Michel Bonnin, Tarik Ait Si Selmi
 Centre orthopédique Paul-Santy-Mermoz, 24, avenue Paul-Santy, 69008 Lyon, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Dual mobility cups have become the implant of choice for older patients with a high risk of dislocation. However, to our knowledge, no study has explored the possibility of metal ion production with these implants that incorporate a polyethylene-on-metal bearing. This led us to conduct a prospective study to determine whether use of a dual mobility cup is accompanied by increased levels of nickel and chromium in the blood.

Hypothesis

Use of a dual mobility cup is accompanied by an increase of nickel and chromium levels in the blood.

Methods

Between 2012 and 2015, 16 consecutive patients were enrolled in the study. They underwent primary hip arthroplasty with a ceramic Biolox™ head (CeramTec, Plochingen, Germany), Corail™ titanium alloy stem (DePuy Synthes, Saint Priest, France) and a Novae™ dual mobility cup (SERF, Décines-Charpieu, France) consisting of 19% chromium (Cr) and 13–15% nickel (Ni). Patients who had other potential sources of nickel or chromium in their body (joint implants, dental implants, etc.) were excluded. The blood levels (μg/L) of nickel and chromium were measured preoperatively and at 2 years’ follow-up by an independent laboratory (Biomnis) using inductively coupled plasma mass spectrometry. The upper limits set by the laboratory were<0.87μg/L for chromium and<1.0μg/L for nickel. AP and lateral X-rays of the pelvis were taken preoperatively and at each postoperative follow-up visit to look for signs of loosening. The Postel-Merle-d’Aubigné (PMA) score was determined preoperatively and at each postoperative follow-up visit. Surgical revision procedures for any cause were also documented.

Results

The mean follow-up was 29 months [13–39]. Preoperatively, blood nickel ion levels were measured in 7 patients; they were below 1μg/L in 6 patients (86%) and at 1.5μg/L in 1 patient (14%). The mean preoperative chromium ion levels (n=7) was 0.2μg/L [0–0.8μg/L]. Postoperatively, all 16 enrolled patients had their blood ion levels checked at a mean follow-up of 29 months. The nickel ion levels averaged 1.69±1.49 [0.2–5.6] (with 4/16 having>2μg/L and 12/16>1μg/L) and the chromium ion levels averaged 0.5±0.11 [0.4–0.7] (with no patients>0.7μg/L). There were no signs of loosening or osteolysis on the follow-up radiographs. The mean PMA score at 2 years was 17.8 [17,18].

Conclusion

We found that dual mobility cups generate increased nickel but not chromium ions in the blood. The levels measured are comparable to those for other orthopedic implants such as spine implants. The clinical consequences of these increased levels are not known. Nevertheless, there were no clinical or radiological signs of loosening, although the follow-up was only 2 years.

Level of evidence

IV, Cohort study.

Le texte complet de cet article est disponible en PDF.

Keywords : Hip replacement, Double mobility, Public health, Nickel, Chromium


Plan


© 2018  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 104 - N° 8

P. 1179-1182 - décembre 2018 Retour au numéro
Article précédent Article précédent
  • The Merete BioBall system in hip revision surgery: A systematic review
  • Carlos D. Novoa, Mustafa Citak, Akos Zahar, Roxana E. López, Thorsten Gehrke, José L. Rodrigo
| Article suivant Article suivant
  • Risk factors for cut-out after internal fixation of trochanteric fractures in elderly subjects
  • Antoine Morvan, Jacques Boddaert, Judith Cohen-Bittan, Hervé Picard, Hugues Pascal-Mousselard, Frédéric Khiami

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.