S'abonner

Distribution of left ventricular trabeculation across age and gender in 140 healthy Caucasian subjects on MR imaging - 19/12/18

Doi : 10.1016/j.diii.2018.08.014 
Z. Bentatou a, b, , M. Finas c, P. Habert d, F. Kober a, M. Guye a, b, S. Bricq e, A. Lalande e, f, J. Frandon c, JN. Dacher g, B. Dubourg g, G. Habib d, h, J. Caudron g, S. Normant g, S. Rapacchi a, b, M. Bernard a, A. Jacquier a, b
a UMR CNRS 7339, Aix-Marseille University, 13385 Marseille cedex 05, France 
b Centre de Résonance Magnétique Biologique et Médicale, Hôpital de la Timone, AP–HM, 13385 Marseille cedex 05, France 
c Department of Radiology, CHU de Grenoble, 38043 Grenoble cedex 9, France 
d Department of Cardiology, Aix-Marseille Université, Hôpital de la Timone, AP–HM, 13385 Marseille cedex 05, France 
e Le2i, University de Bourgogne-Franche Comté, 21000 Dijon, France 
f MRI Department, University Hospital of Dijon, 21000 Dijon, France 
g Cardiac Imaging Unit, Department of Radiology, hôpital universitaire de Rouen, 76031 Rouen, France 
h IRD, IHU-Méditerranée Infection, université d’Aix Marseille, MEPHI, AP–HM, 13385 Marseille cedex 05, France 

Corresponding author. CEMEREM, CHU de Marseille, 27, boulevard Jean-Moulin, 13385 Marseille cedex 05, France.CEMEREM, CHU de Marseille27, boulevard Jean-MoulinMarseille cedex 0513385France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose

The purpose of this study was to quantify the distribution of trabeculated (T) and compact (C) left ventricular (LV) myocardium masses in a healthy Caucasian population against age, gender and LV parameters, and to provide normal values for T, C and T/C.

Materials and methods

One hundred and forty healthy subjects were prospectively recruited and underwent cardiac MRI at 1.5T with a stack of short-axis cine sequences covering the entire LV. End-diastolic volume (EDV), C and T masses were quantified using a semi-automatic method. Ejection fraction (EF) and T/C ratio were computed.

Results

We included 70 men and 70 women with a mean age of 44±14 (SD) years (range: 20–69 years). The mean EF was 63.7±6.3 (SD) % (range: 50.7–82.0%), the mean EDV was 75.9±16.2 (SD) mL/m2 (range: 36.4–112.2mL/m2), the mean C mass was 53.9±11.2 (SD) g/m2 (range: 26.5–93.4g/m2) and the mean T mass was 4.9±2.4 (SD) g/m2 (range: 1.1–11.4g/m2). The T/C ratio was 9.2±4.5% (range: 2.0–29.4%). Multivariate ANOVA test showed that the compact mass was influenced by EDV (P<0.0001), EF (P=0.001) and gender (P<0.0001), and the trabeculated mass depended on EDV (P<0.0001), gender (P=0.002) and age (P<0.0001), while the T/C ratio was only influenced by age (P=0.0003). Spearman test showed a correlation between EDV and C (r=0.60; P<0.0001),T (r=0.46; P<0.0001) and T/C ratio (r=0.26; P=0.0023).T and T/C ratio correlated with EF (r=−0.18, P=0.0373; r=−0.18, P=0.0321, respectively).

Conclusion

While the compact and trabeculated myocardium masses appear to relate separately to the cardiac function, age and gender, their ratio T/C appears to only decrease with age. Furthermore, we propose here normal values for T, C and T/C in a cohort of healthy Caucasians subjects.

Le texte complet de cet article est disponible en PDF.

Keywords : Myocardium, Left ventricular remodeling, Left ventricular function, Cardiac magnetic resonance imaging (CMR)


Plan


© 2018  Soci showét showé françaises de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 99 - N° 11

P. 689-698 - novembre 2018 Retour au numéro
Article précédent Article précédent
  • Postoperative MR imaging features after superior semicircular canal plugging in Minor syndrome
  • J. Seroussi, C. Hautefort, A. Gillibert, R. Kania, J.-P. Guichard, H. Vitaux, P. Herman, E. Houdart, A. Attyé, M. Eliezer
| Article suivant Article suivant
  • Breast mass characterization using shear wave elastography and ultrasound
  • S. Hari, S.B. Paul, R. Vidyasagar, E. Dhamija, A.D. Adarsh, S. Thulkar, S. Mathur, V. Sreenivas, S. Sharma, A. Srivastava, V. Seenu, R. Prashad

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.