S'abonner

ANGIOPLASTY AND STENTING OF THE CERVICAL CAROTID BIFURCATION UNDER FILTER PROTECTION: A PROSPECTIVE STUDY IN A SERIES OF 53 PATIENTS - 21/03/08

Doi : JNR-03-2005-32-2-0150-9861-101019-200502222 

G. Bonaldi [1 et 2],

L. Aiazzi [3],

F. Baruzzi [2],

F. Biroli [4],

A. Facchinetti [2],

P. Fachinetti [5],

A. Lunghi [1],

F. Terraneo [3]

Voir les affiliations

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Angioplastie et stenting de la bifurcation carotide cervicale avec filtre de protection : étude prospective de 53 patients

Le but de ce travail est d’évaluer la tolérance, la fiabilité, la facilité d’utilisation et l’intérêt des filtres de protection pendant l’angioplastie et le « stenting » des sténoses de la bifurcation carotide. Sur une période de 42 mois, 53 patients porteurs d’une sténose de la bifurcation carotide ont été traités par angioplastie et/ou « stenting » en utilisant des filtres de protection cérébrale de différents types. Les sténoses étaient d’origine athéroscléreuse (n = 48), post-chirurgicale (n = 4) et post-radiothérapique (n = 1). Les résultats anatomiques étaient dans tous les cas satisfaisants, avec une restauration satisfaisante du diamètre artériel. Il y eut trois cas d’accident cerébral majeur (5,6 %) et un cas mineur (1,9 %). Deux de ces accidents (un majeur et un mineur) sont survenus dans les heures suivant le traitement et correspondaient à un syndrome d’hyperperfusion hémorragique. Une hémiparésie avec dysphasie, survenue 2 jours après le traitement, était liée à un ethrombose subaiguë avec occlusion du stent. Un patient présenta au cours des deux semaines qui suivirent le traitement, trois épisodes de cécité monoculaire homolatéraux à l’endoprothèse. En conclusion, dans notre pratique, la mise en place de filtres de protection cérébrale ajoute quelques minutes à la durée totale du traitement ; des dissections de la paroi artérielle ou thrombi intraluminaux n’ont jamais été observés ; les spasmes distaux de l’artère carotide ont toujours été résolutifs. Le contenu des filtres a été étudié ; du matériel de plaque n’a été observé qu’une seule fois (présence probablement liée à notre technique initiale de stenting sans prédilatation). La principale limite technique est la survenue d’une coagulation au sein du filtre, observée dans 16 cas, responsable d’une occlusion de la membrane du filtre et d’un ralentissement ou d’un arrêt de la circulation. Un tel événement est prévenu par une anticoagulation plus importante qui pourrait être à l’origine de deux infarctus hémorragiques. De plus nous avons observé deux autres complications majeures ce qui porte le taux de complications dans cette série à 7,5 %. À notre avis, la tolérance des filtres n’est pas aujourd’hui démontrée et de grandes précautions sont nécessaires lors de leur utilisation.

The aim of this study is to assess safety, reliability, ease of use and usefulness of filter protection devices d uring angioplasty and stenting of stenotic lesions of the cervical carotid bifurcation. Over a period of 42 months, 53 patients harboring a cervical carotid bifurcation stenotic lesion were treated, by angioplasty and/or stenting using filter protection devices of different kinds. The stenosis was atherosclerotic in 48 cases, post-surgical in four and post-radiation in one case. In all cases, the treatment was successful, with good restoration of the luminal diameter. There were three major strokes (5.6%) and one minor stroke (1.9%). Two of these (one major, one minor) occurred a few hours after the stenting procedure and both seemed by all evidence due to a hemorrhagic hyperperfusion syndrome. One hemiparesis and dysphasia occurred two days after the procedure, secondary to subacute thrombosis with occlusion of the stent. One patient complained of three episodes of decrease in visual acuity of the eye ipsilateral to the stenting in the two weeks following treatment. In conclusion, in our experience, use of the devices adds only few minutes to the procedure time; direct lesions of the arterial wall, such as dissections or intraluminal thrombi, related to the use of filters were never observed, and spasm of the distal I.C.A. also proved rapidly regressive. The content of all filters, if any, was histologically examined, but plaque material was found only in one case, probably owing to our primary stenting technique without use of pre-dilation. The major technical drawback is in-filter coagulation, which occurred in 16 cases, occluding the membrane of the filter and thus slowing or blocking intracranial flow. Such an event can be counteracted by a more aggressive anti-coagulation protocol, which could, however, be responsible for the two complications with hemorrhagic brain infarction. Furthermore, we observed two other major neurological events, which bring the incidence of neurological complications in this series as high as 7.5%. Therefore, it is our opinion that safety of filters is not yet proven, and consequently great care must be taken in their use.


Mots clés : angioplastie , artère carotide , endoprothèse

Keywords: angioplasty , carotid artery disease , stents


Plan



© 2005 Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 32 - N° 2

P. 109-117 - mars 2005 Retour au numéro
Article précédent Article précédent
  • TRAITEMENT ENDOVASCULAIRE DES ANÉVRYSMES NON ROMPUS DE L’ARTÈRE CÉRÉBRALE MOYENNE
  • J.R. Vanzin, C. Mounayer, M. Piotin, L. Spelle, H. Boissonnet, J. Moret
| Article suivant Article suivant
  • RELATION QUANTITATIVE DES MODIFICATIONS DE LA DIFFUSION ET DE LA PERFUSION AU SEIN DU PARENCHYME CÉRÉBRAL AU COURS DE L’ACCIDENT ISCHÉMIQUE AIGU
  • M. Hamon, R.M. Marié, P. Clochon, O. Coskun, J.M. Constans, F. Viader, P. Courthéoux, J.C. Baron

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.