Efficacité des ballons Pro-ACT™ dans le traitement de seconde ligne de l’incontinence urinaire d’effort post-prostatectomie après échec des bandelettes sous-urétrales - 10/01/19

Pro-ACT™ device implantation efficiency in second line treatment of post-radical prostatectomy urinary incontinence after sub-urethral male sling failure

Doi : 10.1016/j.purol.2018.09.007 
M. Nicolas a, , b , S. Droupy a , P. Costa a
a Service d’urologie du CHU de Nîmes, 30029 Nîmes, France 
b Service d’urologie du CHU de Nancy-Brabois, 54500 Vandœuvre-lès-Nancy, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 9
Iconographies 1
Vidéos 0
Autres 0

Résumé

Introduction

Les ballons Pro-ACT™ (Uromedica, Inc., MN, États-Unis) sont une technique mini-invasive de traitement de première intention de l’incontinence urinaire d’effort post prostatectomie (IUE post-PR) non sévère comme les bandelettes sous urétrales (BSU). Peu de données d’efficacité sont disponible quant à leur utilisation en traitement de seconde ligne après échec des BSU.

Objectif

Évaluer l’efficacité des ballons Pro-ACT™ dans le traitement de seconde ligne de IUE post-PR non sévère après échec des BSU.

Patient et méthodes

Étude rétrospective, monocentrique de patient ayant eu une pose de ballons Pro-ACT™, après échec de BSU (17 Advance™, 1 TOMS™) entre 2009 et 2015. Les résultats sur la continence étaient évalués par le nombre de protections par jour et par l’évaluation de la qualité de vie par le questionnaire I-QOL. La guérison était définie par l’absence de protections systématiques et l’amélioration par une réduction de plus de 50 % du nombre de protection.

Résultats

Dix-huit patients ont été inclus avec un suivi médian de 21,5 [14–44] mois. Deux patients (11,1 %) avaient un antécédent de radiothérapie pelvienne adjuvant à la PR. Le nombre médian de protections par jour était de 2 [1–3], après la pose de BSU et avant la pose des ballons. Après la pose des ballons Pro-ACT™, le nombre médian de protections par jour était de 0 [0–1], avec 77,7 % des patients guéris et 22,2 % améliorés. Le score médian de qualité de vie I-QOL, était 52,2 [23,3–62,6] et de 83 [31,8–97,7], respectivement avant et après la pose de ballons Pro-ACT™ (p<0,001). Neuf (60 %) patients, évaluaient la gravité de leur incontinence comme légère, quatre (26,6 %) comme moyenne et deux (13,3 %) comme sévère, après la pose des ballons. Le volume médian d’ajustement des ballons était de 3 [2–6] mL.

Conclusion

Les ballons Pro-ACT™ ont une efficacité significative sur la prise en charge de l’IUE post-PR après échec des BSU et peuvent être proposés en seconde intention.

Niveau de preuve

3.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction and objectives

The periurethral adjustable balloons (PUAB) Pro-ACT™ are less invasive technique to treat non-severe forms of post-radical prostatectomy urinary incontinence (pRP-UI), like sub-urethral trans-obturator male sling. Few data of efficiency are available for their use in second line treatment after male sling failure.

Objective

To evaluate the efficiency of PUAB Pro-ACT™ (Uromedica, Inc., MN, USA) in the second line treatment for non-severe pRP-UI after male sling failure.

Materials and methods

Single center retrospective study of patients treated with male sling (17 Advance™, 1 TOMS™) between 2009 and 2015. The continence results were evaluated by the number of pad per day and the quality of life assessment by the I-QOL questionnaire. The “cure” was defined as no pad and “improved” as decreased more than 50 % of pads use.

Results

Eighteen patients were included with median follow-up of 21.5 [14–44] months. Two patients (11.1 %) had a past history of pelvic radiotherapy. The median pads per day used was 2 [1–3] after male sling insertion and before Pro-ACT™ device insertion. After Pro-ACT™ device insertion, the median pads per day used was 0 [0–1], with 77.7 % of patients cured and 22.2 % improved. The median quality of life score I-QOL, was 52.2 [23.3–62.6] and 83 [31.8–97.7], respectively before and after Pro-ACT™ device insertion (P<0.001). Nine (60 %) patients rated their incontinence severity as mild, four (26.6 %) as middle and two (13.3 %) as severe, after balloon insertion. The median volume of adjustment was 3 [2–6] mL.

Conclusions

The PUAB Pro-ACT™ have a significant efficiency for use after male sling failure and can be used in second line therapy.

Level of evidence

3.

Le texte complet de cet article est disponible en PDF.

Mots clés : Incontinence urinaire masculine, Prostatectomie radicale, Ballons péri-urétraux ajustables Pro-ACT™, Bandelettes sous urétrales, I-QOL

Keywords : Male urinary incontinence, Radical prostatectomy, Adjustable continence therapy Pro-ACT™ device, Sub-urethral sling, I-QOL


Plan


© 2018  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 29 - N° 1

P. 36-44 - janvier 2019 Retour au numéro
Article précédent Article précédent
  • Migration in last decade to high-risk prostate cancer after radical prostatectomy
  • P.-M. Patard, M. Roumiguié, T. Prudhomme, N. Doumerc, M. Thoulouzan, X. Gamé, A. de la Taille, P. Rischmann, M. Soulié, L. Salomon, J.-B. Beauval
| Article suivant Article suivant
  • Évaluation du niveau sonore dans un bloc opératoire d’urologie
  • L. Carillo, A. Devic, M. Soulié, X. Gamé

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.