S'abonner

Changes in cerebral hemodynamics after carotid stenting: evaluation with CT perfusion studies - 21/03/08

Doi : JNR-06-2006-33-3-0150-9861-101019-200603853 

A. Trojanowska [1],

A. Drop [1],

T. Jargiello [2],

J. Wojczal [3],

M. Szczerbo-Trojanowska [2]

Voir les affiliations

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Modifications hemodynamiques cérébrales après stenting carotide : études en scanner de perfusion

Objectif : Déterminer les modifications des paramètres de perfusion cérébrale en scanner de perfusion après angioplastie transluminale et pose de sent.

Matériel et méthodes : 74 patients porteurs d’une sténose serrée carotide symptomatique (> 70 %) ont été étudiés en scanner de perfusion avant et après (en moyenne 70 heures et 172 jours après traitement) : sténose unilatérale (n = 50), sténose et occlusion de l’artère carotide interne controlatérale (n = 24). L’appareil était un scanner multidétecteurs (Light Speed Ultra Advantage, GE Healthcare, USA). Les cartographies suivantes ont été générées : valeurs absolues du débit sanguin cérébral (CBF), du volume sanguin cérébral (CBV) et temps de transit moyen (MTT).

Résultats : Dans le groupe des patients porteurs d’une sténose unilatérale isolée, les résultants étaient les suivants : deficit de perfusion homolatéral à la sténose chez 84 % des patients, allongement du MTT (6,2-6,8 s), diminution des valeurs du CBF (40-46 ml/100 g/min) et légère augmentation du CBV (3,2 ml/100 g). Dans ce groupe, 3 jours après le stenting, 30 % des patients avaient des defects de perfusion et après 6 mois seulement 6 %. Dans le roupe des patients porteurs d’une sténose carotide et occlusion de l’artère carotide interne controlatérale, des déficits sévères de la perfusion bihémisphérique étaient retrouvés chez 100 % des patients et une hypoperfusion était observée chez 17 % seulement des patients 6 mois après le stenting.

Conclusion : Les déficits de perfusion cérébrale observée chez la majorité des patients porteurs de sténose carotide tendent à s’améliorer considérablement après stenting carotide lors des contrôles à long terme.

Purpose: To determine changes in cerebral perfusion parameters, based on CT perfusion imaging, in patients after unilateral transluminal angioplasty and stent placement.

Material and methods: 74 patients with symptomatic high – grade internal carotid artery stenosis (>70%) were studied with CT perfusion imaging before and – on average – 70 hours and 172 days after carotid stent placement. There were 50 patients with unilateral carotid artery stenosis and 24 with stenosis and accompanying contralateral internal carotid artery occlusion. CT examination was performed using a multidetector helical CT scanner (Light Speed Ultra Advantage, GE Healthcare, USA). Maps showing the absolute values of cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) were generated.

Results: In a group with unilateral carotid artery stenosis perfusion deficits were present in 84% of patients, ipsilaterally to stenosis. MTT elongation was noted (6.2-6.8s) together with decreased values of CBF (40-46ml/100g/min) and slightly increased CBV (3.2ml/100g). In this group, 3 days after stenting, 30% of patients had perfusion deficits, and after 6 months only 6%. In a group with carotid artery stenosis and contralateral artery occlusion severe perfusion deficits were noted in both hemispheres and they were present in 100% of patients. 6 months after stenting hypoperfusion was observed only in 17% of patients.

Conclusions: Brain perfusion deficits, observed in a majority of patients with carotid artery stenosis tend to improve considerably after carotid artery stenting, in long – term follow up.


Mots clés : sténose carotide , ischémie cérébrale , stenting , CT perfusion

Keywords: carotid artery stenosis , cerebral ischaemia , carotid artery stenting , CT perfusion


Plan



© 2006 Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 33 - N° 3

P. 169-174 - juin 2006 Retour au numéro

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.