S'abonner

Cement augmentation of glenoid baseplate screws does not improve primary stability in reversed shoulder arthroplasty: A cadaveric study - 31/03/19

Doi : 10.1016/j.otsr.2018.10.006 
Benjamin Bockmann a, Martin Bäumlein b, Rainer Koch b, Jens Figiel c, Philipp Lechler b, René Aigner b, Christopher Bliemel b, Ludwig Oberkircher b, Steffen Ruchholtz b, Michael Frink b,
a Department of Orthopaedics and Trauma Surgery, St. Josef Hospital, Ruhr University Bochum, Germany 
b Center for Orthopeadics and Trauma Surgery, University Hospital Gießen and Marburg, 35043 Marburg, Germany 
c Department of Diagnostic and Interventional Radiology, University Hospital Gießen and Marburg, 35043 Marburg, Germany 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Cuff tear arthritis and complex proximal humeral fractures are common pathologies that are frequently addressed by the implantation of a reversed shoulder prosthesis. The present cadaveric study aimed to analyze the effect of cement augmentation of the glenoid component on the primary stability in geriatric patients.

Hypothesis

Cement augmentation of glenoid baseplate screws has an influence on primary stability in reversed shoulder arthroplasty (RSA).

Materials and methods

Glenoid base plates (Delta Xtend, DePuy Synthes, Westchester, USA) were implanted in 6 pairs of formalin-fixated scapulae of 4 female and 2 male donors (average age 83 years). Two angle stable screws were placed at the superior and inferior position. Cement augmentation was performed with 2ml bone cement (Kyphon, Medtronic, Minneapolis, USA) per screw in right specimens. Afterwards, biomechanical testing with 600 to 1000N (100 cycles) at a 65° abduction angle was performed. Finally, a load-to-failure analysis was conducted.

Results

No implant loosening was observed during cyclic tests from 600N to 1000N. In addition no difference in the plastic deformation was detected at 600N (p=0.301), 700N (p=0.522), 800N (p=0.480), 900N (p=0.521) and 1000N (p=0.748). Load-to-failure analyses revealed implant loosening at 3314N (SD 823N) in the cement-augmented implants and at 3059N (SD 974N) in scapulae with non-cemented screws (p=0.522).

Discussion

Cement-augmented fixation of the glenoid component did not result in an increased primary stability in this study. Thus, the application of cement should be critically assessed considering associated risks and increased costs.

Level of proof

Basic science study, controlled laboratory study.

Le texte complet de cet article est disponible en PDF.

Keywords : Reverse shoulder arthroplasty, Glenoid fixation, Cement, Augmentation, Primary stability


Plan


© 2018  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 105 - N° 2

P. 219-223 - avril 2019 Retour au numéro
Article précédent Article précédent
  • Views on a new surgical assistance method for implanting the glenoid component during total shoulder arthroplasty. Part 2: From three-dimensional reconstruction to augmented reality: Feasibility study
  • Julien Berhouet, Mohamed Slimane, Maxime Facomprez, Min Jiang, Luc Favard
| Article suivant Article suivant
  • Do we need to stabilize and treat the os acromiale when performing reverse shoulder arthroplasty?
  • Ali Er?en, Serkan Bayram, Ata Can Atalar, Mehmet Demirhan

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.