S'abonner

Outcomes and function of conoid ligament on the basis of postoperative radiographic findings of arthroscopic stabilization for the distal clavicle fractures - 31/03/19

Doi : 10.1016/j.otsr.2018.12.005 
Katsumi Takase , Kengo Yamamoto
 Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku Shinjuku-ku, 160-0023 Tokyo, Japan 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose

Distal clavicle fractures are divided into three types according to Neer's classification. These fractures are usually treated with a sling to immobilize the upper extremity, however, the treatment of type 2 fractures remain controversial. We focused on the anatomical basis of these fractures in which disruptions in the conoid ligament led to the distraction between the two bony fragments. In this study, we report an arthroscopic procedure for conoid ligament reconstruction and its therapeutic outcomes, and discuss the function of the reconstructed conoid ligament.

Hypothesis

Arthroscopic conoid ligament reconstruction alone is sufficient to retain the posteriorly displaced proximal fragment of the clavicle in its reduced position.

Materials and methods

A retrospective cohort study were conducted on 18 patients with type 2 distal clavicle fractures. Arthroscopic techniques were performed with the patients in the beach chair position. Dacron artificial ligament® was used to reconstruct the conoid ligament, and the internal bone fixation materials included an EndoButton® on the coracoid process side and a screw with a spiked washer on the clavicle side. Preoperative assessment was performed via plain radiography or three-dimensional computed tomography to evaluate the displacement of the proximal fragment. Although the displacement was superoposterior in all the cases, the acromioclavicular joint was maintained. The mean duration of postoperative follow-up was 2 years and 5 months.

Result

There were no injury-related complications during the surgery and bony union was achieved within 3 months after surgery. Evaluation using 3DCT also showed that the preoperative superoposterior displacement of the proximal fragment of the clavicle was immediately reduced postoperatively, and this reduced position was maintained until the final follow-up examination.

Conclusions

We achieved good results by indirectly reducing fractures of the distal clavicle with conoid ligament damage using the minimally invasive surgical technique of arthroscopic conoid ligament reconstruction. Anatomical reconstruction of the conoid ligament might stabilize not only the superior displacement of the displaced proximal fragment of the clavicle but also its posterior displacement.

Study design

Case series with no comparison study.

Level of evidence

4, retrospective cohort study.

Le texte complet de cet article est disponible en PDF.

Keywords : Distal clavicle fracture, Arthroscopic reconstruction, Superoposterior displacement of the clavicle, Conoid ligament


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 105 - N° 2

P. 281-286 - avril 2019 Retour au numéro
Article précédent Article précédent
  • Anatomical study of the position and orientation of the coracoclavicular ligaments: Differences in bone tunnel position by gender
  • Terufumi Shibata, Teruaki Izaki, Satoshi Miyake, Nobunao Doi, Yozo Shibata, Yutaka Irie, Katsuro Tachibana, Takuaki Yamamoto
| Article suivant Article suivant
  • Gleno-humeral abduction measurement in patients with Ehlers-Danlos syndrome
  • David Cypel

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.