S'abonner

Three-Dimensional inferior vena cava for assessing central venous pressure in patients with cardiogenic shock - 17/04/19

Doi : 10.1016/j.acvdsp.2019.01.038 
R. Huguet 1, , Damien. Fard 1, 2, Thomas. D’humières 1, 2, O. Brault-Meslin 1, 2, Louis. Nahory 1, 2, L. Faivre 1, 2, J.L. Dubois-Randé 1, 2, Julien. Ternacle 1, 2, Léopold. Oliver 1, 2, P. Lim 1, 2
1 Cardiologie, CHU Henri Mondor - UPEC 
2 Inserm U955, Creteil, France 

Corresponding author.

Résumé

Background

Evaluation of central venous pressure (CVP) by inferior vena cava (IVC) measurements is crucial in the management of patients with cardiogenic shock to optimize drugs therapy. IVC has a complex 3-dimensional (3D) shape but measurements used to estimate CVP remain based on 2-dimensional (2D) echocardiographic imaging.

Purpose

The aim of this study was to investigate the accuracy of CVP estimation by IVC size and collapsibility index obtained using 3D-echocardiography compared with 2D in patients with cardiogenic shock.

Methods

Eighty consecutive echocardiographic examinations performed in 33 patients (72±15 years, left ventricular ejection fraction=19±10%) admitted for cardiogenic shock were prospectively included. Two and three-dimensional images of the IVC, performed at baseline and when CVP was10mmHg, were acquired simultaneous with invasive measurement of CVP, both at rest and during sniff test. 2D and 3D IVC diameters, 3D IVC area and collapsibility index (IVCCI) were assessed. The eccentricity index (EI) was computed from 3D data as the ratio of maximum over minimum IVC diameter. The cut-off value of 10mmHg of CVP defined patient with euvolemia hemodynamic status.

Results

At rest, the IVC diameter averaged 23±7mm by 2D and 25±8×19±7mm by 3D. IVC had an eccentric shape (EI=1.3) that increased when CVP was ≤10mmHg and during sniff test (P<0.001). IVC measurements by 2D and 3D were correlated with CVP. The best correlation was obtained with IVCCI derived from 2D diameters (R=-0.69) and 3D areas (R=−0.82). Using the cutoff value of 50% for IVCCI, a discrepancy between invasive CVP measurements and IVCCI has been observed for 11 examinations (13%) by 2D but only one was misclassified by 3D. Inter and intra-observer reproducibility for IVC area was 7±6% and 5±3%, respectively (Fig. 1).

Conclusions

In patients with cardiogenic shock, IVCCI from area by 3D echocardiography is reproducible and accurate to evaluate CVP.

Le texte complet de cet article est disponible en PDF.

Plan


© 2019  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 11 - N° 1P2

P. e291-e292 - avril 2019 Retour au numéro
Article précédent Article précédent
  • Multimodality imaging guidance for percutaneous paravalvular leak closure: Insights from the multicenter FFPP register
  • S. Hascoët, G. Smolka, F. Bagate, K. Hadeed, Y. Lavie-Badie, H. Bouvaist, C. Dauphin, F. Bauer, M. Nejjari, L. Mangin, G. Bonnet, V. Ciobotaru, G. Leurent, N. Hammoudi, A. Aminian, C. Karsenty, S. Armero, D. Champagnac, J. Ternacle, M.A. Isorni
| Article suivant Article suivant
  • Correlation between acute pulmonary embolism severity index (PESI) and prognostic of acute pulmonary embolism
  • M. Hassine, H. Touil, M. Ben Massoued, M. Mahjoub, N. Bouchahda, Z. Dridi, F. Betbout, Habib. Gamra

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.