S'abonner

Initial clinical experience of synthetic MRI as a routine neuroimaging protocol in daily practice: A single-center study - 18/04/19

Doi : 10.1016/j.neurad.2019.03.002 
Kyeong Hwa Ryu a, Hye Jin Baek a, , Jin Il Moon a, Bo Hwa Choi a, Sung Eun Park a, Ji Young Ha a, Kyung Nyeo Jeon a, Kyungsoo Bae a, Dae Seob Choi b, Soo Buem Cho c, Yedaun Lee d, Young Jin Heo e
a Department of Radiology, Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, Republic of Korea 
b Department of Radiology, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, 79 Gangnam-ro, Jinju 52727, South Korea 
c Department of Radiology, Ewha Womans University College of Medicine, 1071 Anyangcheon-ro, Yangcheon-gu, Seoul 07985, South Korea 
d Department of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, 875 Haeundae-ro, Haeundae-gu, Busan 48108, South Korea 
e Department of Radiology, Inje University College of Medicine, Busan Paik Hospital, 75 Bokji-ro, Busanjin-gu, Busan, 47392, South Korea 

Corresponding author at: Department of Radiology, Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, South Korea.Department of Radiology, Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital11 Samjeongja-ro, Seongsan-guChangwon51472South Korea
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Thursday 18 April 2019
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background and purpose

We investigated the clinical feasibility of synthetic MRI with a 4-min single scan using a 48-channel head coil as a routine neuroimaging protocol in daily practice by assessing its diagnostic image quality.

Methods

We retrospectively reviewed the imaging data of 89 patients who underwent routine brain MRI using synthetic MRI acquisition between February 2017 and April 2017. Image quality assessments were performed by two independent readers on synthetic T1 fluid-attenuated inversion recovery (FLAIR), T2-weighted, T2 FLAIR, and phase-sensitive inversion recovery sequences acquired using multiple-dynamic multiple-echo imaging. Interobserver reliability between the two readers was assessed using kappa (κ) statistics.

Results

On a 4-point assessment scale, the overall image quality and anatomical delineation provided by synthetic brain MRI were found to be good with scores of more than 3 points for all sequences except for the T2 FLAIR sequence. The synthetic T2 FLAIR sequence provided sufficient image quality but showed more pronounced artifacts, especially the CSF pulsation artifact and linear hyperintensity along the brain surface. Interobserver agreement for evaluating image quality of all synthetic sequences was good to excellent (κ, 0.61–0.99; P < 0.001).

Conclusion

Synthetic MRI can be acceptable as a routine clinical neuroimaging protocol with a short scan time. It can be helpful to design customized and flexible neuroimaging protocols for each institution.

Le texte complet de cet article est disponible en PDF.

Keywords : Synthetic MRI, MAGiC, Brain MRI, Routine neuroimaging protocol, Diagnostic image quality


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.