S'abonner

Oxygen uptake efficiency slope in children with congenital heart disease versus healthy children - 14/08/19

Doi : 10.1016/j.acvdsp.2019.06.010 
Arthur Gavotto a, f, , D’arcy Vandenberghe a, f, Hamouda Abassi a, Helena Bertet c, d, Valerie Macioce c, Marie-Christine Picot c, d, Sophie Guillaumont a, e, f, Stefan Matecki b, f, Pascal Amedro a, b, f
a Pediatric and Congenital Cardiology Department, M3C Regional Reference CHD Centre, University Hospital, Montpellier, France 
b PhyMedExp, CNRS, Inserm, University of Montpellier, Montpellier, France 
c Epidemiology and Clinical Research Department, University Hospital, Montpellier, France 
d Clinical Investigation Centre, INSERM, University of Montpellier, France 
e Pediatric Cardiology and Rehabilitation Unit, St-Pierre Institute, Palavas-Les-Flots, France 
f Pediatric Functional Exploration Laboratory, Physiology Department, University Hospital, Montpellier, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Cardio-pulmonary exercise test (CPET) provides accurate evaluation of physical capacity and disease severity in children with congenital heart disease (CHD). However, in clinical practice, full participation to obtain optimal measure of VO2max may be difficult. As an alternative, the oxygen uptake efficiency slope (OUES) is a reproducible and reliable parameter measured during CPET, which does not require a maximal exercise to be interpretable. This study aimed to evaluate the OUES of a large cohort of children with CHD, and to compare the results with those of healthy controls. We also intended to identify, in this specific population, the clinical and CPET variables associated with the OUES.

Methods and results

This cross-sectional multicenter study enrolled 709 children (407 CHD and 302 healthy controls). The association of clinical characteristics with weight-normalized OUES (OUESkg) was studied using a multivariable analysis. The mean OUESkg was significantly lower in CHD than in healthy controls (respectively 38.6±8.5 and 43.9±8.5; P<0.001). The OUESkg was predominantly affected in the most severe CHD. The OUESkg correlated well with VO2max (r=0.85, P<0.001). The decrease of OUESkg was associated with increased age, increased BMI, number of cardiac catheter or surgical procedures, female gender and decreased FVC (Z-score).

Conclusion

The OUES is significantly impaired in children with CHD and strongly correlates with VO2max. The OUES has the same clinical determinants as VO2max and therefore may be of interest in submaximal exercise.

Le texte complet de cet article est disponible en PDF.

Keywords : Cardio-pulmonary exercise test, Congenital heart disease, Oxygen uptake efficiency slope, OUES, Pediatrics


Plan


© 2019  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 11 - N° 4

P. e383-e384 - septembre 2019 Retour au numéro
Article précédent Article précédent
  • Impact of skin and nasal decontamination before cardiac surgery on postoperative Staphylococcus infection rate in children
  • L. Savary, A. De Luca, N. Soulé, P. Neville, J.M. El Arid, J. Chantreuil, Z. Maakaroun, B. Lefort
| Article suivant Article suivant
  • Mid-term outcomes after percutaneous pulmonary valve implantation in complex right ventricular outflow tracts using the “folded” Melody® valve technique
  • Estíbaliz Valdeolmillos, Zakaria Jalal, Stanimir Georgiev, Andreas Eicken, Michael Hofbeck, Ludger Sieverding, Marc Gewillig, Caroline Ovaert, Helene Bouvaist, Jean-Benoit Thambo, Younes Boudjemline

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.