S'abonner

A triple-layered closing technique using the recti muscles to augment implant coverage in eye enucleation after maxillofacial radiotherapy: A case report - 27/09/19

Doi : 10.1016/j.jormas.2019.09.003 
C. Keilani a, b, c, , M.-L. Herdan a
a Oculoplastic and facial surgery department–The Fondation Adolphe de Rothschild Hospital, 29, rue Manin, Paris, France 
b Sorbonne University, 91–105, boulevard de l’hôpital, Paris, France 
c Assistance Publique–Hôpitaux de Paris, 3, avenue Victoria, Paris, France 

Corresponding author at: Adolphe de Rothschild Foundation, 29, rue Manin, 75019 Paris, France.Adolphe de Rothschild Foundation29, rue ManinParis75019France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 27 September 2019
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Eye enucleation (EE) of a previously irradiated orbit can lead to difficult wound closure due to the soft tissues fibrosis such as Tenon's capsule and conjunctiva. We, here, report a technique modification for EE surgery after facial radiotherapy that may decrease implant exposure by using recti muscles native tissue to reinforce the anterior implant coverage. A 71-year-old African male presented in 2003 a right orbital extranodal marginal zone B-cell lymphoma of the mucosa-associated lymphoid tissue (MALT) type. He was treated with chemotherapy followed by whole orbital radiotherapy. His right vision remained impaired due to phtisis bulbi secondary to facial radiotherapy. By 2017, he developed right painful phthisis bulbi. Radiological systemic staging did not reveal any recurrence or metastasis. Because of the history of neoplasia, the right eye had to be enucleated. Due to tissue fibrosis secondary to radiotherapy, we took care to preserve as much conjunctiva and Tenon as possible. EE was performed under general anesthesia. EE consisted of a standard procedure with a modified triple-layered closing technique. The four recti muscles were attached with 5-0 Vicryl to the anterior part of the implant by passing the needle through the tunnels and tying the suture. The horizontal muscles were spread with a forceps to cover the lateral and medial part of the implant. The vertical muscles were spread with a forceps to cover the superior and the inferior part of the implant. Finally the edges of the recti muscles were sutured to each other with 5-0 Vicryl to create a muscle layer. Tenon's capsule and conjunctiva were closed separately, using horizontal interrupted 6-0 Vicryl sutures. One year after surgery, wound closure was complete with no sign of extrusion. The triple-layered closing technique using the recti muscles in EE represents a potentially viable alternative to augment implant coverage in case of Tenon and conjunctival fibrosis secondary to facial radiotherapy.

Le texte complet de cet article est disponible en PDF.

Keywords : Eye enucleation (EE), Triple-layered closing technique, Maxillofacial radiotherapy, Radiation-induced fibrosis, Orbital lymphoma


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.