S'abonner

Identification of plasma miR-148a as a noninvasive biomarker for hepatocellular carcinoma - 29/09/19

Doi : 10.1016/j.clinre.2018.12.008 
Juqiang Han a, Jiarui Li b, Yun Qian c, Wenpeng Liu d, Jiguang Liang b, Zhigang Huang e, Shuai Wang a, Caiyan Zhao d,
a Department of Liver Disease, PLA Army General Hospital, Beijing city, Beijing, PR China 
b Department of Interventional Radiography, The First Hospital of Jilin University, Changchun city, Jilin Province, PR China 
c Department of Digestive Disease, Shenzhen University General Hospital, Shenzhen city, Guangdong Province, PR China 
d Department of Infectious disease, The Third Hospital of Hebei Medical University, Shijiazhuang city, Hebei Province, PR China 
e Department of Epidemiology, Guangdong Medical University, Dongguan city, Guangdong Province, PR China 

Corresponding author at: Ziqiang road, Shijiazhuang city, Hebei Province, 050051, PR China.Ziqiang roadShijiazhuang cityHebei Province050051PR China

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 9
Iconographies 4
Vidéos 0
Autres 0

Highlights

We found a significant decrease in plasma miR-148a expression in HCC patients.
AUROC analysis confirmed diagnostic of miR-148a in the detection of HCC.
Plasma miR-148a is a potential non-invasive biomarker for HCC screening.
Detection of miR-148a might be a complementary approach to AFP for predicting HCC occurrence.

Le texte complet de cet article est disponible en PDF.

Summary

Background

The detection of microRNA (miRNA) markers in plasma is a potential strategy for hepatocellular carcinoma (HCC) screening. The aim of this study was to characterize miR-148a in the peripheral plasma as a non-invasive biomarker for the diagnosis of HCC.

Methods and methods

Quantification of miR-148a was performed on 346 plasma samples, including 155 patients with HCC, 96 patients with liver cirrhosis and 95 healthy controls using quantitative real-time PCR (qRT-PCR). Plasma miR-148a was compared before and after the removal of the tumor in 97 cases of HCC. Receiver operating characteristic (ROC) curves were generated to analyze predictive value of plasma miR148a in HCC.

Results

Plasma miR-148a levels were significantly lower in HCC patients compared to those with liver cirrhosis (P < 0.01) or healthy controls (P < 0.01). The area under receiver operating characteristic (AUROC) curve for plasma miR-148a was 0.919, with a sensitivity of 89.6 % and a specificity of 89.0% for HCC patients compared with liver cirrhosis. In HCC patients with negative or low AFP, AUROC values for plasma miR-148a were 0.949, with a sensitivity of 90.6% and a specificity of 92.6%. The removal of primary HCC tumor led to increased plasma miR-148a levels (P < 0.0001), indicating that miR-148a is a HCC-specific biomarker.

Conclusion

Plasma miR-148a is a potential non-invasive biomarker for HCC screening, especially for those with negative or low AFP. Detection of miR-148a might be a complementary approach to AFP for predicting HCC occurrence.

Le texte complet de cet article est disponible en PDF.

Keywords : Hepatocellular carcinoma,miR-148a, Biomarker, Diagnosis


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 43 - N° 5

P. 585-593 - octobre 2019 Retour au numéro
Article précédent Article précédent
  • MicroRNA-101 suppresses liver fibrosis by downregulating PI3K/Akt/mTOR signaling pathway
  • Yang Lei, Qing-lan Wang, Li Shen, Yan-yan Tao, Cheng-hai Liu
| Article suivant Article suivant
  • Naturally occurring NS5A and NS5B resistant associated substitutions in HCV and HCV/HIV patients in iranian population
  • Amitis Ramezani, Kazem Baesi, Mohammad Banifazl, Minoo Mohraz, Farzin Khorvash, Majid Yaran, Payam Tabarsi, Amir hosein Dalirrooyfard, Fatemeh Motevalli, Anahita Bavand, Arezoo Aghakhani

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.