S'abonner

Etude prospective comparant plusieurs techniques de congélation de faibles nombres de spermatozoïdes humains - 05/10/19

Prospective comparison of different techniques for cryopreservation of small numbers of human spermatozoa.

Doi : 10.1016/j.gofs.2019.09.014 
Charlène Herbemont 1, 2, Sonia Mnallah 1, Michael Grynberg 3, 4, Christophe Sifer 1, 2,
1 Service de Biologie de la Reproduction-CECOS, Hôpitaux Universitaires Paris Seine Saint-Denis, AP-HP, 93140, Bondy, France 
2 Université Paris XIII, Sorbonne Paris Cité, UFR SMBH, 93000, Bobigny, France 
3 Service de Médecine de la Reproduction, Hôpitaux Universitaires Paris Seine Saint-Denis, AP-HP, 93140, Bondy, France 
4 Unité Inserm U1133, Université Paris-Diderot, 75013, Paris, France 

Auteur correspondant:
Sous presse. Manuscrit accepté. Disponible en ligne depuis le Saturday 05 October 2019
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Résumé

Objectif: L’objectif de cette étude était de déterminer si la congélation de faibles nombres de spermatozoïdes humains par vitrification est plus performante que la congélation lente, et si oui, quel support est le plus adapté.

Méthodes: Cette étude prospective expérimentale a été menée dans le laboratoire d’Assistance Médicale à la Procréation d’un Centre Hospitalier Universitaire. Plusieurs recueils de sperme ont été réalisés par le même donneur fertile après signature d’un consentement. Les spermatozoïdes sélectionnés étaient congelés par la technique de congélation lente ou vitrifiés dans deux supports différents : la Cell Sleeper et le Stripper tip.

Résultats: Les taux de récupération, mobilité et survie après vitrification en Cell Sleeper étaient significativement plus élevés qu’après congélation lente. Seul le taux de récupération était statistiquement plus important en Cell Sleeper, lorsque comparé au Stripper tip. Le temps de récupération par spermatozoïde était plus rapide en Cell Sleeper par rapport aux deux autres techniques. Par ailleurs, une différence significative était obtenue en comparant les paramètres précédents entre le Stripper tip et la congélation lente, concluant également à la supériorité de la vitrification en Stripper tip. Enfin, le temps théoriquement nécessaire pour injecter un ovocyte était significativement plus court pour les deux techniques de vitrification par rapport à la congélation lente, et plus court en Cell Sleeper par rapport au Stripper tip.

Conclusions: La vitrification, notamment en Cell Sleeper, semble être la technique la plus adaptée à la conservation de faibles nombres de spermatozoïdes.

Le texte complet de cet article est disponible en PDF.

Abstract

Objectives: This study aimed to determine if vitrification is more efficient than the slow freezing method when cryopreservation of small numbers of human spermatozoa is needed and, if so, which device is the most suitable.

Methods: This is a prospective experimental study conducted in a university-affiliated assisted reproductive center. Ejaculates were obtained from the same fertile man after written consent. Selected sperm were cryopreserved by slow freezing method or vitrified in two different devices: Cell Sleeper and Stripper tip.

Results: Vitrification in Cell Sleeper provided significantly higher recovery, motility and survival rates than slow freezing. Only recovery rate was higher in Cell Sleeper than when using Stripper tip. Moreover, recovery time per spermatozoon was faster in Cell Sleeper than in the two other groups. Furthermore, statistical significance was achieved when comparing the four above parameters between Stripper tip and slow freezing, concluding to the superiority of vitrification in Stripper tip as well. Finally, the theorical time needed per injected oocyte was significantly shorter after vitrification in the two devices than when using slow freezing, and shorter in Cell Sleeper in comparison with Stripper tip.

Conclusions: Vitrification, in particular using Cell Sleeper, appears as the most suitable method to cryopreserve small numbers of spermatozoa.

Le texte complet de cet article est disponible en PDF.

Mots clés : cryopreservation, faible nombre de spermatozoïdes, vitrification, congélation lente, supports

Keywords : Cryopreservation, Small number of Spermatozoa, Vitrification, Slow freezing, Devices



© 2019  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.