S'abonner

Étude prospective comparant plusieurs techniques de congélation de faibles nombres de spermatozoïdes humains - 06/11/19

Prospective comparison of different techniques for cryopreservation of small numbers of human spermatozoa

Doi : 10.1016/j.gofs.2019.09.014 
C. Herbemont a, b, S. Mnallah a, M. Grynberg c, d, C. Sifer a, b,
a Service de biologie de la reproduction-CECOS, hôpitaux universitaires Paris Seine Saint-Denis, AP–HP, 93140 Bondy, France 
b UFR SMBH, université Paris XIII, Sorbonne Paris Cité, 93000 Bobigny, France 
c Service de médecine de la reproduction, hôpitaux universitaires Paris Seine Saint-Denis, AP–HP, 93140 Bondy, France 
d Unité Inserm U1133, université Paris-Diderot, 75013 Paris, France 

Auteur correspondant : service d’histologie-embryologie-cytogénétique-CECOS, centre hospitalier universitaire Jean-Verdier, Assistance publique–Hôpitaux de Paris, 93143 Bondy, France.service d’histologie-embryologie-cytogénétique-CECOS, centre hospitalier universitaire Jean-Verdier, Assistance publique–Hôpitaux de ParisBondy93143France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 0
Vidéos 0
Autres 0

Résumé

Objectif

L’objectif de cette étude était de déterminer si la congélation de faibles nombres de spermatozoïdes humains par vitrification est plus performante que la congélation lente, et si oui, quel support est le plus adapté.

Méthodes

Cette étude prospective expérimentale a été menée dans le laboratoire d’assistance médicale à la procréation d’un centre hospitalier universitaire. Plusieurs recueils de sperme ont été réalisés par le même donneur fertile après signature d’un consentement. Les spermatozoïdes sélectionnés étaient congelés par la technique de congélation lente ou vitrifiés dans deux supports différents : la Cell Sleeper et le Stripper tip.

Résultats

Les taux de récupération, mobilité et survie après vitrification en Cell Sleeper étaient significativement plus élevés qu’après congélation lente. Seul le taux de récupération était statistiquement plus important en Cell Sleeper, lorsque comparé au Stripper tip. Le temps de récupération par spermatozoïde était plus rapide en Cell Sleeper par rapport aux deux autres techniques. Par ailleurs, une différence significative était obtenue en comparant les paramètres précédents entre le Stripper tip et la congélation lente, concluant également à la supériorité de la vitrification en Stripper tip. Enfin, le temps théoriquement nécessaire pour injecter un ovocyte était significativement plus court pour les deux techniques de vitrification par rapport à la congélation lente, et plus court en Cell Sleeper par rapport au Stripper tip.

Conclusions

La vitrification, notamment en Cell Sleeper, semble être la technique la plus adaptée à la conservation de faibles nombres de spermatozoïdes.

Le texte complet de cet article est disponible en PDF.

Abstract

Objectives

This study aimed to determine if vitrification is more efficient than the slow freezing method when cryopreservation of small numbers of human spermatozoa is needed and, if so, which device is the most suitable.

Methods

This is a prospective experimental study conducted in a university-affiliated assisted reproductive center. Ejaculates were obtained from the same fertile man after written consent. Selected sperm were cryopreserved by slow freezing method or vitrified in two different devices: Cell Sleeper and Stripper tip.

Results

Vitrification in Cell Sleeper provided significantly higher recovery, motility and survival rates than slow freezing. Only recovery rate was higher in Cell Sleeper than when using Stripper tip. Moreover, recovery time per spermatozoon was faster in Cell Sleeper than in the two other groups. Furthermore, statistical significance was achieved when comparing the four above parameters between Stripper tip and slow freezing, concluding to the superiority of vitrification in Stripper tip as well. Finally, the theorical time needed per injected oocyte was significantly shorter after vitrification in the two devices than when using slow freezing, and shorter in Cell Sleeper in comparison with Stripper tip.

Conclusions

Vitrification, in particular using Cell Sleeper, appears as the most suitable method to cryopreserve small numbers of spermatozoa.

Le texte complet de cet article est disponible en PDF.

Mots clés : Cryopréservation, Faible nombre de spermatozoïdes, Vitrification, Congélation lente, Supports

Keywords : Cryopreservation, Small number of Spermatozoa, Vitrification, Slow freezing, Devices


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 47 - N° 11

P. 797-801 - novembre 2019 Retour au numéro
Article précédent Article précédent
  • L’ADN fœtal libre circulant : un outil d’évaluation du risque de survenue de complications obstétricales ?
  • C. Duvillier, T. Quibel, C. Felsenheld, L. Hupin-Genty, C. Cohen, F. Vialard
| Article suivant Article suivant
  • Recours au test virologique HPV dans la prise en charge des atypies glandulaires en Alsace entre 2014 et 2016
  • V. Goillot, M. Paté, A. Delaitre, C. Akladios, J.-J. Baldauf, L. Lecointre

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.