S'abonner

Long-term survival of hybrid total hip arthroplasty with the uncemented CLS cup, cemented Müller cobalt-chromium stem, and 28-mm Metasul™ bearings: Retrospective review of 115 hips after a minimum of 17.8 years - 07/11/19

Doi : 10.1016/j.otsr.2019.06.019 
Roger Erivan a, , Guillaume Villatte a, Thibaut Lecointe b, Aurélien Mulliez c, Stéphane Descamps a, Stéphane Boisgard a
a Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, F-63000 Clermont–Ferrand, France 
b Université Clermont Auvergne, CHU Clermont-Ferrand, F-63000 Clermont-Ferrand, France 
c Délégation à la Recherche Clinique et aux Innovations (DRCI), CHU Clermont-Ferrand, F-63000 Clermont-Ferrand, France 

Corresponding author at: Orthopaedic and Trauma Surgery Department, Hôpital Gabriel-Montpied, CHU de Clermont-Ferrand, BP 69, 63003 Clermont-Ferrand, France.Orthopaedic and Trauma Surgery Department, Hôpital Gabriel-Montpied, CHU de Clermont-FerrandBP 69Clermont-Ferrand63003France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Hard-on-hard bearings require a meticulous implantation technique but may be associated with lower wear rates in young active patients. Among them, metal-on-metal (MoM) bearings have been blamed for specific complications including adverse reactions to metal debris and metal hypersensitivity. These complications have been chiefly reported with large-head MoM implants (except when used for hip resurfacing). Most of the published data on small-head MoM implants were obtained using uncemented stems. To our knowledge, no information on outcomes beyond 15 years is available for small-head MoM implants with cemented cobalt-nickel-chromium (Co-Ni-Cr) stems, which might increase the risk of complications. The objective of this study was to collect long-term follow-up data on patients who underwent hybrid total hip arthroplasty (THA) with 28-mm MoM Metasul™ bearings in order to assess: (1) long-term survival (based on the revision rate), (2) and the occurrence of adverse reactions to metal debris documented during revision.

Hypothesis

Survival of 28-mm Metasul™ bearings used with hybrid THA is acceptable.

Patients and methods

A single-centre retrospective study was conducted in consecutive patients managed using 28-mm Metasul™ bearings in a press-fit cup, with a cemented Co-Ni-Cr stem. Follow-up was at least 17 years. The clinical and radiographic data were analysed. Mean age at surgery was 57.3±7.9 years (range, 29.6–75.3 years).

Results

The study included 115 hips with a mean follow-up of 20.3±0.8 years (range, 17.8–21.6 years). Survival to revision for any reason was 86.10% (95% CI, 79.8–92.4%) and survival to revision for aseptic loosening was 92.6% (95% CI, 87.7–97.6). Half the specimens obtained during revision showed a macrophage reaction and a non-specific inflammatory infiltrate. No patient experienced complications specifically related to the use of Metasul™ bearings with a cemented Co-Ni-Cr stem.

Discussion

Long-term survival of 28-mm MoM Metasu™ bearings was close to that of metal-on-polyethylene bearings and lower than that of ceramic-on-ceramic or small-head MoM bearings in other studies. No complications specifically related to the use of small-head MoM bearings with a cemented Co-Ni-Cr stem were recorded.

Level of evidence

IV, retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Aseptic lymphocyte-dominated vasculitis-associated lesion, Adverse reaction to metal debris, Metal-on-metal, Total hip arthroplasty, Survival


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 105 - N° 7

P. 1289-1295 - novembre 2019 Retour au numéro
Article précédent Article précédent
  • Texture analysis of trabecular bone around RM-Pressfit cementless acetabulum in a series of 46 patients during a 5 year period
  • Augustin Coupry, Louis Rony, Florian Ducellier, Laurent Hubert, Daniel Chappard
| Article suivant Article suivant
  • Patients with musculoskeletal dysplasia undergoing total joint arthroplasty are at increased risk of surgical site Infection
  • Harshadkumar Patel, Kyle H. Cichos, Andrew S. Moon, Gerald McGwin, Brent A. Ponce, Elie S. Ghanem

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.