S'abonner

How is the outcome of the Limb Preservation System™ for reconstruction of hip and knee? - 19/12/19

Doi : 10.1016/j.otsr.2019.09.030 
Maria Anna Smolle , Joerg Friesenbichler, Marko Bergovec, Magdalena Gilg, Werner Maurer-Ertl, Andreas Leithner
 Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Thursday 19 December 2019
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

Despite tremendous advantages in the development and application of megaprostheses in tumour and revision surgery, complications are still not infrequently observed. Only two studies investigating the outcome of the LPS™ system in the proximal femur and distal femur/proximal tibia have been published thus far. Herein, mid-term implant survival rates one of the largest cohort of patients treated with the LPS™-system are presented aiming tp answer: 1) How is the outcome of the LPS™ system in the proximal femur and distal femur/proximal tibia? 2) Which factors are associated with altered implant survival? 3) What is the cumulative risk of complications according to Henderson?

Hypothesis

The LPS™-system is associated with high complication rates that depend on implant site, with infections being most common.

Patients and methods

Fifty-seven patients who received the LPS™-system at the proximal femur (n=31), distal femur (n=21) and proximal tibia (n=5) between 2004 and 2010 for oncological (n=40) or non-oncological (n=17) causes, were retrospectively included. Median follow-up was 5.0 years (range, 0-12.4 years). Complications were classified according to Henderson into instability/soft tissue failure (type 1), aseptic loosening (type 2), structural failure (type 3), periprosthetic infection (type 4), tumour progression (type 5). Competing-risk-analyses were applied to estimate implant survival with death as the competing event.

Results

Twenty-six patients (45.6%) developed a complication, of whom 9 (29.0%) had a proximal femoral and 17 (65.4%) a distal femoral/proximal tibial implant. Type 4 complications were most common (n=11), followed by type 3 (n=6, including 2 yoke-fractures), type 1 and 2 (n=4 each), and type 5 (n=1). The only factor associated with the development of complications in the multivariate model was a distal femoral/proximal tibial implant (hazard-ratio: 7.418, 95% confidence-interval: 2.193-26.096, p=0.001), irrespective of reason for reconstruction and use of muscular flaps. The cumulative-incidence of failure including all complications was 34.3%, 40.7% and 67.1% at 3, 5 and 10 years, respectively.

Discussion

The LPS™-system may be used for proximal femoral reconstructions both in the oncological and non-oncological setting. Rates of complications are higher in our cohort than reported in literature for other, comparable, megaprosthesis systems. Especially in the distal femur/proximal tibia, complication rates were high, partially attributable to the former implant design leading to fractures of the yoke-mechanism. As the implant has been remodelled after these issues became evident, there is no objection to use this megaprosthesis system today.

Level of evidence

IV, Observational Study.

Le texte complet de cet article est disponible en PDF.

Keywords : Tumour endoprosthesis, Reconstruction, LPS™ system, Implant survival


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.