S'abonner

Ulnar facet locking screw locations of volar locking plates placed without flexor pollicis longus tendon contact: A cadaver study - 31/12/19

Doi : 10.1016/j.otsr.2019.12.002 
Yuki Kikuchi a, Kotaro Sato a, , Yoshikuni Mimata a, Kenya Murakami a, Gaku Takahashi b, Minoru Doita a
a Department of Orthopaedic Surgery, Iwate Medical University, 1-1-1, Idaidori, Yahaba-cho, Shiwa-gun, 028-3694 Iwate, Japan 
b Department of Critical Care Medicine, Iwate Medical University, 1-1-1, Idaidori, Yahaba-cho, Shiwa-gun, 028-3694 Iwate, Japan 

Corresponding author at: Department of Orthopaedic Surgery, Iwate Medical University, 1-1-1, Idaidori, Yahaba-cho, Shiwa-gun, 028-3694 Iwate, Japan.Department of Orthopaedic Surgery, Iwate Medical University1-1-1, Idaidori, Yahaba-cho, Shiwa-gunIwate028-3694Japan
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Tuesday 31 December 2019
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

The volar locking plate (VLP) system provides stable fixation and is widely used for distal radius fractures. Studies have shown that irritation of the implant prominence is a risk factor for flexor tendon rupture, especially of the flexor pollicis longus (FPL). Contact between VLPs and flexor tendons should be avoided. We aimed to investigate the ulnar facet locking screw locations of various VLPs placed without FPL tendon contact in cadaver wrists.

Hypothesis

We hypothesized that ulnar facet locking screws would be in the vicinity of the subchondral bone when the plate is placed in the most distal position without FPL tendon contact.

Materials and methods

The study assessed two variable-angles and four fixed locking plates. We placed each plate in six different cadavers, resulting in 36 different plate-cadaver combinations. Plates were placed in the most distal position without FPL tendon contact. We drilled the most ulnar hole (hole A) and the second ulnar hole (hole B) of the distal row. All drilling procedures were performed using a specific jig for each fixed locking plate. For variable-angle locking plates, we drilled with a fixed jig for each plate. We obtained lateral radiographs when the drill penetrated the dorsal cortex and measured the distance between the drill and the articular surface.

Results

With regard to hole A, the mean distances between the drill and the center of the articular surface were 2.6–5.2mm for the four fixed locking plates and 4.9–5.6mm for the two variable-angle locking plates. With regard to hole B, the mean distances between the drill and the center of the articular surface were 3.8–5.9mm for the four fixed locking plates and 5.5–5.9mm for the two variable-angle locking plates.

Discussion

When clinicians place a VLP without FPL tendon contact, the distance between the ulnar facet screws and the center of the articular surface is over 3mm in most cases. Surgeons should select variable-angle drilling for strong articular support when using variable-angle locking plates.

Level of evidence

III, diagnostic Level.

Le texte complet de cet article est disponible en PDF.

Keywords : Distal radius fracture, Volar locking plate, Flexor pollicis longus, Tendon rupture, Anatomic study


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.