S'abonner

Efficacy of venous recanalization by non-invasive pulsed ultrasonic cavitation therapy on swine model of acute deep venous thrombosis with 14 days of follow-up - 06/01/20

Doi : 10.1016/j.acvdsp.2019.09.308 
L. Khider 1, , G. Goudot 1, 2, C. Del Giudice 1, 3, T. Mirault 1, 3, A. Galloula 1, P. Bruneval 1, M. Vion 4, M. Remond 4, M. Tanter 2, M. Pernot 2, E. Messas 1, 3
1 Médecine vasculaire, Hôpital Européen Georges-Pompidou 
2 Inserm U1273, CNRS FRE 2031, Physics for Medicine 
3 Inserm U970 PARCC, Paris Descartes University–USPC Sorbonne Paris Cité University 
4 CardiaWave, Paris, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Background

Post thrombotic syndrome is a frequent complication of deep venous thrombosis, associated with high morbidity. Treatments currently available are invasive. Pulsed cavitational ultrasound therapy (PCUT) is a new technique to destroy remotely soft tissue. We demonstrated that PCUT was able to recanalize non-invasively in in-vitro model of human blood clot.

Purpose

We aim to test the safety and efficacy of venous recanalization by non-invasive PCUT in vivo swine model of acute venous thrombosis.

Methods

All the experiments were performed on White large X Landrace swine. We induced an acute femoral deep venous thrombosis by using endovascular approach combined with local injection of thrombin. A 3cm length occlusive thrombosis was obtained after 2hours. Swine were divided in three groups: one with PCUT without follow-up (n=11), one with PCUT and follow-up at 14days (n=8), and a control group also followed for 14days (n=5). Acutely and during follow up all swine received curative anticoagulation. To achieve PCUT, a 2.25MHz transducer (Imasonic©) centered by a linear probe was used and cavitation was obtained in the centre of the vein. Effectiveness of recanalization was evaluated by echo-Doppler and phlebography. Safety was assessed by Doppler ultrasound and by histological analysis of vein, artery and lungs.

Results

Among the 24swine, we obtained 22occlusive venous thromboses and 2 partials. The median length of the thrombus was 26±4.4mm. Acutely, thrombosis recanalization was obtained among the 19swine with PCUT with median treatment duration of 33min. After a 14-day follow-up, 75% of recanalisation remains permeable vs. 0% of vein permeable in the no therapy group (P=0.008). Residual diameter was 2.6±1.2mm, 50% of the venous diameter. No embolism or pulmonary infarction was observed in all pigs (Fig. 1).

Conclusion

We have demonstrated in vivo the safety and the efficacy of PCUT for non-invasive venous recanalization, persistent after 2weeks.

Le texte complet de cet article est disponible en PDF.

Plan


© 2019  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 12 - N° 1

P. 141-142 - janvier 2020 Retour au numéro
Article précédent Article précédent
  • Prediction of the development of carbohydrate disorders in patients with arterial hypertension based on an assessment of the levels of interleukin-10 and glycosylated haemoglobin
  • L. Zhuravlyova, M. Kulikova
| Article suivant Article suivant
  • An N-/L-Type calcium channel blocker, cilnidipine, reduces electrical and structural atrial remodeling associated with atrial fibrillation in a chronic dog model
  • J. Guichard, K. Tajiri, F. Xiong, A. Da Costa, S. Nattel

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.