Résumé

Background

X-rays are widely used for the TAVR realization, for the pre-TAVR assessment (coronary angiography±PCI and computed tomography), and sometimes in the aftermath of the intervention (electrophysiology study, pacemaker implantation). TAVR currently becomes an alternative to surgical valve replacement for patients at intermediate risk, a population that is likely to experience an increase of the radiation-induced cancer risk following TAVR.

Purpose

The main objective of our study was therefore to evaluate the overall exposure to ionizing radiation for patients benefiting from a trans-femoral TAVR.

Methods

All patients who underwent trans-femoral TAVR for a symptomatic aortic stenosis in our centre over a 26 months period were included. Dosimetric indicators (i.e. dose area product or dose length product) of pre-procedural coronary angiography and computed tomography, TAVR procedure, and any post-procedural interventions (electrophysiology study and/or pacemaker implantation) were collected and converted into an effective dose. The primary endpoint was the cumulative effective dose, calculated by summing effective doses received during the TAVR procedure and during pre- and post-procedural irradiating exams.

Results

One hundred and ninteen trans-femoral TAVR procedures were included, and the mean cumulative effective dose was 37.3 mSv. When only three procedures were necessary (71% of the population), 75% of the overall effective dose was from the computed tomography, while only 11% of this dose came from the TAVR procedure itself and 14% came from the coronary angiogram (Table 1, Fig. 1).

Conclusion

Overall exposure to ionizing radiation for patients benefiting from a trans-femoral TAVR seemed acceptable, and the majority of the overall effective dose was from the computed tomography.

Le texte complet de cet article est disponible en PDF.

Plan


© 2019  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 12 - N° 1

P. 85-86 - janvier 2020 Retour au numéro
Article précédent Article précédent
  • Outcome of normal-flow low-gradient “severe” aortic stenosis with preserved left ventricular ejection fraction: A propensity matched study
  • G. Chadha, Y. Bohbot, D. Rusinaru, S. Marechaux, C. Tribouilloy
| Article suivant Article suivant
  • Comparison of transcarotid vs. complex transfemoral access in patients undergoing transcatheter aortic-valve implantation (TAVI)
  • R. Choteau, F. Leclercq, M. Akodad, J. Macia, C. Chamard, B. Albat, G. Cayla, T. Gandet

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.