S'abonner

Intérêt de la manipulation des plans en tomodensitométrie pour identifier le dysmorphisme sacré et évaluer la variabilité de hauteur pour prédire la possibilité de fixation par vis trans-sacrée - 11/01/20

The usefulness of reformatting CT scanning plane to distinguish sacral dysmorphism and introducing the variable of elevated height for predicting the possibility of trans-sacral screw fixation

Doi : 10.1016/j.rcot.2019.11.025 
Hoe Jeong Chung a, Jisu Park a, Hoon-Sang Sohn a, Gu-Hee Jung b, c,
a Department of Orthopedic Surgery, Wonju College of Medicine, Wonju Severance Christian Hospital, Yonsei University, 20, Ilsan-ro, Wonju-si, 26426 Gangwon-Do, République de Corée 
b Department of Orthopaedic surgery, Gyeongsang national university, college of medicine, Gyeongsang national university changwon hospital, 11, Samjeongja-ro, Seongsan-gu, 51472 Changwon-Si, Korea 
c Medical ICT Convergence research center, Institute of Health Sciences, college of Medicine, Gyeongsang National University, 816 Beongil 15, 52727 Jinju-daero, Jinju-si, Korea 

Auteur correspondant.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Saturday 11 January 2020
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Introduction

Ilio-sacral screw fixation has been used for sacral fractures and sacroiliac joint dislocations. However, it is associated with significant complications including screw loosening with backing-out and loss of reduction. Trans-sacral screw fixation is indicated for rigid fixation in specific circumstances including bilateral posterior ring injuries, osteoporotic bone, or to supplement other types of posterior ring fixation.

Hypothesis

The reformatting the CT scanning plane may distinguish sacral dysmorphism and predict the possibility of trans-sacral screw fixation by introducing the new indicator.

Material and methods

The CT data of 112 adult cadavers (61 males and 51 females) were imported into Mimics® software and a 7.0mm-sized trans-sacral screw was virtually placed in the ideal position of S1. The osseous widths around screw in the axial images (AxWS1) were measured. By reformatting the CT scanning plane parallel to the superior endplate of S1, the AxWRS1 was measured and the height of elevated segment in the upper sacrum (elevated height) was assessed as a new preoperative indicator.

Results

Cortical violation around screw was detected in 26 models and was considered as sacral dysmorphism. The average AxWS1 was measured as 13.70±2.76mm in the non-dysmorphism group, and 5.81±2.19mm in the dysmorphism group, with statistical difference (p<0.001). By reformatting the CT scanning plane, the average AxWRS1 increased to 16.61±2.79mm in the non-dysmorphism group, and 8.04±2.62 in the dysmorphism group, and the difference was statistically significant (p<0.001). The elevated height was 3.29±4.19mm in the non-dysmorphism group, and 17.52±3.09mm in the dysmorphism group, and the differences were statistically significant (p<0.001). Based on the ROC curve analysis, the cut-off value of elevated height was 12.90mm (sensitivity 1.0 and specificity 1.0).

Discussion

By reformatting the CT scanning plane, the osseous width around screw was widened, and the new preoperative indicator of elevated height could be introduced to predict the possibility of trans-sacral screw fixation into S1. If the elevated height exceeded 13mm, the pelvis was assigned to sacral dysmorphism and thus, could not apply the trans-sacral screw fixation into S1.

Level of evidence

III, controlled laboratory study.

Le texte complet de cet article est disponible en PDF.

Keywords : Pelvic ring injury, Posterior ring fixation, Screw fixation



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.