S'abonner

Comparison of a novel hybrid hook locking plate fixation method with the conventional AO hook plate fixation method for Neer type V distal clavicle fractures - 30/01/20

Doi : 10.1016/j.otsr.2019.10.014 
Joongbae Seo, Kang Heo, Seong-Jun Kim, Jun-Kyom Kim, Hee-Jung Ham, Jaesung Yoo
 Department of Orthopaedic Surgery, Dankook University College of Medicine, Cheonan, Korea 

Corresponding author at: Dankook university hospital, Chungnam 330-715, Cheonan Republic of Korea.Dankook university hospitalChungnam 330-715Cheonan Republic of Korea

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

The conventional AO hook locking compression plate (LCP) (Synthes, Solothurn, Switzerland) has only three holes for lateral fragments; therefore it is not suitable for use during the fixation of small-comminuted fragments in some cases. Recently, a novel hybrid hook LCP (TDM, Seoul, Korea) was developed to overcome this limitation. Here, we evaluated the clinical and radiologic outcomes of a novel hybrid hook LCP for Neer type V distal clavicle fractures compared to the outcomes of a conventional AO hook plate.

Methods

Seventy-eight consecutive patients who underwent hook LCP fixation for Neer type V distal clavicle fractures were included. The subjects were divided into 2 groups: the conventional AO hook LCP group and the novel hybrid hook LCP group. For clinical assessments, the American Shoulder and Elbow Surgeons (ASES) score, Korean shoulder score (KSS), and Constant score were recorded. The percentage modified coracoclavicular distance (MCCD %) was used for the evaluation of fracture reduction. Typical reported complications, such as secondary dislocation, implant failure or loosening, peri-implant fracture, acromion osteolysis, postoperative acromioclavicular joint arthrosis, non-union, or delayed union, were also analyzed.

Results

There were no differences in the clinical outcomes (ASES, KSS, and Constant scores) between the two groups. Bone union was achieved in a significantly shorter period in the hybrid hook LCP group (13.6±2.0weeks) than in the AO hook LCP group (17.5±4.8weeks, p<0.001). Consequently, the time to implant removal was also significantly shorter in the hybrid hook LCP group (4.0±0.5months) than in the AO hook LCP group (5.4±1.1months, p<0.001). The MCCD% showed no significant differences between the treatment groups. There was no statistically significant difference in the complication rate between the two groups; however, the hybrid hook LCP fixation resulted in a lower prevalence of hook-related complications.

Conclusion

The hybrid hook LCP fixation showed satisfactory clinical and radiologic outcomes in comparison with the AO hook LCP fixation. The hybrid hook LCP is useful for multiple screw fixation of inferior comminuted fragments in Neer type V distal clavicle fractures. The bone union was significantly shorter; thus, the time to implant removal was also significantly shorter.

Level of evidence

Level III, Retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Distal clavicle fracture, Neer type V, Coracoclavicular distance, Clavicular hook plate


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 106 - N° 1

P. 67-75 - février 2020 Retour au numéro
Article précédent Article précédent
  • Objective assessment of sleep quality in patients with rotator cuff tears
  • Chase B. Ansok, Lafi S. Khalil, Stephanie Muh
| Article suivant Article suivant
  • Efficacy of bone-end intervention on fracture healing in bisphosphonate-related atypical femoral fractures
  • Umut Canbek, Ulas Akgun, Nevres Hurriyet Aydogan

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.