Mesure de la dose délivrée hors champ à l’utérus lors d’un traitement ORL par protons - 13/02/20

Measurement of out-of-field dose to the uterus during proton therapy of the head and neck

Doi : 10.1016/j.canrad.2019.10.004 
J. le Guevelou a, F. Trompier b, C. Villagrasa b, A. Vela a, A. Isambert b, J. Herault c, J. Thariat a,
a Service de radiothérapie, centre François Baclesse, avenue du Général-Harris, 14000 Caen, France 
b Laboratoire de dosimétrie des radiations ionisantes, Institut de radioprotection et de sûreté nucléaire (IRSN), 92262 Fontenay-aux-Roses, France 
c Centre Lacassagne, 33, avenue Valombrose, 06000 Nice, France 

Auteur correspondant. Laboratoire de physique corpusculaire IN2P3/ENSICAEN, UMR6534, service de radiothérapie, centre François Baclesse, Unicaen, Normandie université, avenue du Général-Harris, 14000 Caen, France.Laboratoire de physique corpusculaire IN2P3/ENSICAEN, UMR6534, service de radiothérapie, centre François Baclesse, Unicaen, Normandie universitéavenue du Général-HarrisCaen14000France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Thursday 13 February 2020
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Résumé

La décision d’irradiation en cours de grossesse repose sur un compromis bénéfice risque de deux ordres : le risque maternel et le risque fœtal. L’objectif de ce travail concernait le risque fœtal et la procédure de mesure de dose à l’utérus en protonthérapie par faisceau pulsé. L’exposition fœtale au cours du traitement est liée à deux sources : la phase de traitement, et la phase de repositionnement. Sur un fantôme anthropomorphe de type Alderson-Rando (170cm, 74kg) en position de traitement, un détecteur de type « Compteur Proportionnel Equivalent-Tissu » (CPET), adapté à l’analyse des champs de rayonnements complexes (neutroniques et photoniques) a été utilisé pour la phase de traitement. Un radiamètre de type AT1123 a été utilisé pour la mesure des photons engendrés par les rayonnements X. Une dosimétrie in vivo a été proposée via des dosimètres radio-photo-luminescents placés à la thyroïde en utilisant un facteur de proportionnalité permettant une vérification de la dose fœtale de manière quotidienne. La phase de traitement engendre des doses à l’utérus plus élevées que pour la phase de positionnement, néanmoins celles-ci restent très faibles. La dose équivalente au niveau de l'utérus pour l’ensemble du traitement est de 840  μSv. Il a pu être mis au point une méthodologie de mesure de la dose hors champ en faisceau pulsé de protonthérapie ORL. La dose fœtale au premier trimestre était bien inférieure aux 100 mGy déterminés par la Commission Internationale de Protection Radiologique.

Le texte complet de cet article est disponible en PDF.

Abstract

The decision to irradiate during pregnancy is based on a risk benefit compromise of two kinds: maternal risk and fetal risk. The aim of this work is to determine the foetal risk, and uterine dose measurement in proton therapy. Foetal exposure during treatment is linked to two sources: the treatment phase, and the repositioning phase. An Alderson-Rando anthropomorphic ghost (170cm, 74kg) was positioned on the table in the treatment position. A tissue-equivalent proportional counter (TEPC), adapted to the analysis of complex radiation fields (neutron and photonics), was used to determine the irradiation related to the treatment phase. An AT1123 radiation survey meter was used to measure photons generated by X-ray radiation. I dosimetry was proposed using radio-photoluminescent dosimeters, allowing for a daily check of the dose received in the uterus. The treatment phase produces higher uterine doses than the positioning phase, but these remain very low. The equivalent dose received in the uterus for the entire treatment is estimated at 840 μSv. Using a methodology for measuring the out-of-field dose with pencil beam scanning proton therapy, the foetal dose in the first trimester was well below the acceptance dose of 100 mGy determined by the International Commission on Radiological Protection.

Le texte complet de cet article est disponible en PDF.

Mots clés : Protonthérapie, Radioprotection, Grossesse, Dosimétrie, Rayonnement secondaire

Keywords : Proton therapy, Radiation protection, Pregnancy, Dosimetry, Stray radiation


Plan


© 2020  Société française de radiothérapie oncologique (SFRO). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.