S'abonner

Optimisation du protocole d’acquisition de la TEP à la fluorocholine dans la détection des lésions parathyroïdiennes - 14/02/20

Optimal FCH PET/CT acquisition protocol for evaluation of hyperfunctioning parathyroid tumors

Doi : 10.1016/j.mednuc.2019.08.003 
P. Lalire a, , D. Morland a, b, c, S. Dejust a, S. Ly f, C. Richard d, M. Zalzali d, A. Moubtakir a, L. Messaoud a, F. Godard a, P. Jallerat a, S. Deguelte e, B. Delemer f, D. Papathanassiou a, b, c
a Unité de médecine nucléaire, institut Godinot, 1 Rue du Général Koenig, 51100 Reims, France 
b Laboratoire de biophysique, UFR de médecine, Reims, France 
c CReSTIC (Centre de recherche en sciences et technologies de l’information et de la communication), EA 3804, université de Reims Champagne-Ardenne, France 
d Unité thyroïde, institut Godinot, Reims, France 
e Service de chirurgie viscérale et endocrinienne, hôpital universitaire Robert-Debré, Reims, France 
f Service d’endocrinologie, diabétologie et nutrition, hôpital universitaire Robert-Debré, Reims, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 10
Iconographies 6
Vidéos 0
Autres 0

Résumé

Si les performances de la TEP à la fluorocholine dans la détection des lésions parathyroïdiennes semblent prometteuses, le délai optimal des acquisitions n’a pas encore été déterminé de façon consensuelle et les protocoles sont variables d’une étude à l’autre. Le but de notre travail était de comparer, de manière qualitative et quantitative, des délais d’acquisition centrés sur 5, 10, 15, 20 et 60min post-injection chez des patients présentant une hyperparathyroïdie primaire et une imagerie traditionnelle équivoque. Cette étude a porté sur 31 patients. Deux observateurs ont rétrospectivement analysé les cinq protocoles étudiés. Toute augmentation focale de la captation de la fluorocholine était localisée et classée selon une échelle de gradation discrète entre 1 et 5 afin d’évaluer la probabilité d’une lésion parathyroïdienne. Le gold standard était l’examen histologique pour les 11 patients opérés. Concernant l’analyse quantitative, les rapports de la SUVmax des foyers parathyroïdiens sur la SUVmean du bruit de fond thyroïdien ont été comparés entre les protocoles. Après injection de 2,5MBq/kg, la TEP à la fluorocholine réalisée vers 60min post-injection (pas de 2min) présentait les meilleures sensibilité et spécificité par lésion (92 % et 100 % respectivement) ainsi que le meilleur rapport lésion sur bruit (médiane de 2). Nous suggérons la réalisation d’une TEP vers 60min après injection, associée à une acquisition précoce afin de ne pas manquer de lésion parathyroïdienne à élimination rapide.

Le texte complet de cet article est disponible en PDF.

Abstract

18F-Fluorocholine (FCH) PET/CT shows very promising potential for detection of hyperfunctioning parathyroid tumors. However, the optimal time to perform imaging after FCH administration has not yet been determined and protocols are highly variable. The aim of this study was to qualitatively and quantitatively compare 5, 10, 15, 20 and 60min post-injection acquisition times in patients with primary hyperparathyroidism and equivocal traditional imaging. Thirty-one patients were included. Two observers retrospectively analyzed the five protocols. Any focal increase in FCH uptake was localized and graded on a discrete gradation scale between 1 and 5 to assess the likelihood of hyperfunctioning parathyroid tumors. Gold standard was histopathological findings for the 11 operated patients. Regarding quantitative analysis, ratio of SUVmax of parathyroid foci on SUVmean of thyroid background (as signal-to-noise ratio) were compared between protocols. After injection of 2.5MBq/kg, FCH PET performed 60min post-injection (2min) had the best sensitivity and specificity by lesion (92% and 100% respectively and the best signal-to-noise ratio (median of 2). We suggest performing PET scan 60min after injection, associated with early acquisition so as not to miss a wash-out hyperfunctioning parathyroid tumors.

Le texte complet de cet article est disponible en PDF.

Mots clés : Tomographie par émission de positons à la fluorocholine, Lésions parathyroïdiennes, Adénome parathyroïdien, Hyperparathyroïdie, Protocole d’acquisition

Keywords : [18F]-fluorocholine PET/CT, Hyperfunctioning parathyroid tumors, Hyperparathyroidism, Parathyroid adenoma, Acquisition protocol


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 44 - N° 1

P. 2-11 - janvier 2020 Retour au numéro
Article précédent Article précédent
  • Remerciements aux lecteurs 2019
| Article suivant Article suivant
  • Cancer différencié de la thyroïde métastatique à propos de 70 cas : impact des nouvelles recommandations de 2017
  • M.M. Larwanou, S. Houda, H. El Ouahabi, N.I. Alaoui

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.