S'abonner

Modification of regional bone mineral density due to femoral rasping in cementless proximally fixed total hip arthroplasty - 05/04/20

Doi : 10.1016/j.otsr.2019.11.030 
Ibraheim El-Daly a, , Andres Rondon b, Stefroy Pinto b, Christine Chappard c, Quentin Grimal b, Elhadi Sariali a, b
a Service d’orthopédie, hôpital Pitié-Salpêtrière, 47-83, boulevard de Hôpital, 75013 Paris, France 
b Inserm UMR S 1146, CNRS UMR 7371, laboratoire d’imagerie biomédicale, Sorbonne université, 75006 Paris, France 
c Osteo-Articular Bioengineering and Bioimaging (B2OA) university Denis Diderot, CNRS, 10, avenue de Verdun, 75010 Paris, France 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Sunday 05 April 2020
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

Three-dimensional planning (3DP) in total hip arthroplasty using computed tomography (CT) to analyze bone mineral density (BMD) at the stem-femur interface has a high reported accuracy and excellent mid-term results in the literature. However, 3DP does not take into account the effect of femoral rasping on BMD distribution within the rasped cavity. Characterizing the impact of femoral rasping on BMD may help avoid mechanical failures, but this data is not accurately investigated. Therefore, we set out a cadaveric study to identify if: (1) Femoral rasping modified regional BMD in areas considered critical for bone anchorage of cementless metaphyseally fixed anatomic stems. (2) In areas of bone-implant contact with an initial high BMD, does femoral rasping increase BMD?

Hypothesis

Femoral rasping increases BMD in some zones considered critical for bone anchorage of cementless metaphyseally fixed anatomic stems within the rasped femoral cavity.

Methods

Four cadaveric femurs were selected to undergo a rasping procedure similar to surgical techniques used for metaphyseally fixed anatomic stems. Images of femurs before and after rasping were obtained with a micro-CT scanner (pixel size 35μm). BMD values before and after rasping were compared in a trabecular bone ring of 3mm thickness around the cavity created by the rasps, in a region extending 3cm above and 2cm below the middle of the lesser trochanter.

Results

Average BMD increased significantly after rasping in 3 of the 4 femurs (13% (0.27 to 0.30) (p=0.004)), 12% (0.32 to 0.36 (p=0.034)) and 15% (0.4 to 0.46 (p=0.001)), while there was no significant variation in the last femur (0.32 to 0.32 (p>0.05)). Increases in regional BMD were significantly higher in the lateral and medial areas, as well as in the most distal femoral regions. There were significantly lower variations of BMD in regions with initially higher BMD.

Discussion

Current opinion considers trabecular bone debris from femoral rasping to have an impact on final stem position and outcome. Our study has demonstrated an overall positive effect of femoral rasping on BMD in the rasped cavity. Understanding this in the context of 3DP may help avoid mechanical failures such as, suboptimal implant fit, fill, and stability as well as femoral fractures during stem implantation.

Level of evidence

IV, Prospective in vitro study.

Le texte complet de cet article est disponible en PDF.

Keywords : Broaching, BMD, Computed tomography, Planning, Compaction


Plan


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.