S'abonner

Texture parameters of R2* maps are correlated with iron concentration and red blood cells count in clot analogs: A 7-T micro-MRI study - 24/05/20

Doi : 10.1016/j.neurad.2019.10.004 
Martin Bretzner a, b, , Renaud Lopes a, b, Ray McCarthy c, Delphine Corseaux d, e, f, Florent Auger a, Gillian Gunning c, Nicolas Beauval i, Antonino Bongiovanni g, Meryem Tardivel g, Charlotte Cordonnier h, Jean-Pierre Pruvo a, b, Sophie Susen d, e, f, Xavier Leclerc a, b, Grégory Kuchcinski a, b
a Inserm U1171 Degenerative & Vascular Cognitive Disorders, University of Lille, 59000 Lille, France 
b CHU de Lille, Department of Neuroradiology, 59000 Lille, France 
c Cerenovus, Neuravi Thromboembolic Initiative, Galway, Ireland 
d Inserm U1011-EGID, Lille, France 
e Institut Pasteur de Lille, Lille, France 
f CHU Lille, Hematology and Transfusion, 59000, Lille, France 
g Bio imaging center Lille Nord-de-France Campus HU, faculté de médecine, Université de Lille, 59000 Lille, France 
h CHU de Lille, Department of Neurology, 59000 Lille, France 
i CHU Lille, Unité Fonctionnelle de Toxicologie, 59000 Lille, France 

Corresponding author at: Department of Neuroradiology, CHU de Lille, rue Emile-Laine, 59000 Lille, France.Department of Neuroradiology, CHU de Lillerue Emile-LaineLille59000France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 4
Vidéos 0
Autres 0

Résumé

Graphical abstract




Le texte complet de cet article est disponible en PDF.

Highlights

RBC count is strongly correlated with iron concentration within clots.
Texture analysis of R2* maps predict the RBC count and iron content of clot analogs.
R2* maps of RBC rich clots present a more coarse texture.
R2* maps of RBC poor clots present a finer texture.

Le texte complet de cet article est disponible en PDF.

Abstract

Background and purpose

Previous studies have suggested that mechanical revascularization in acute ischemic stroke (AIS) patients could be affected by clot histology. In this 7-T micro-MRI study, we used R2* relaxometry of clot analogs to evaluate the relationship between texture parameters of R2* maps and clot constituents.

Materials and methods

Twelve AIS clot analogs were experimentally generated to obtain a wide range of red blood cell concentrations. All clots underwent a MR acquisition using a 7-T micro-MR system. A 3D multi-echo gradient-echo sequence was performed and R2* maps were generated. First order and second order statistics of R2* histograms within the clots were calculated. Iron concentration in clots was measured using absorption spectrometry and red blood cell count (RBC) was obtained by histopathological analysis.

Results

RBC count was strongly correlated with iron concentration within clots (r=0.87, P<.001). Higher RBC count and iron concentration were significantly correlated with first order parameters including: (a) global positive shift of the R2* histogram with higher ‘10th percentile’, ‘median’, ‘mean’ and ‘90th percentile’; (b) increase of the global magnitude of voxel values with higher ‘total energy’ and ‘root mean squared’; (c) greater uniformity of the voxel values with higher ‘uniformity’ and lower ‘entropy’. Second order statistical parameters confirmed that higher RBC count and iron concentration correlated with (a) greater concentration of high gray-level values in the image; (b) more “coarse” texture of R2* maps.

Conclusions

Texture analysis of MRI-R2* maps can accurately estimate the red blood cell count and iron content of AIS clot analogs.

Le texte complet de cet article est disponible en PDF.

Keywords : MRI, Stroke, Clot, Texture analysis, Relaxometry


Plan


 Previous presentation: Annual meeting of the French Society of Neuroradiology (SFNR). Date: the 27th of March 2019. Location: Paris, France. Presentation type: oral communication during a scientific session.


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 47 - N° 4

P. 306-311 - juin 2020 Retour au numéro
Article précédent Article précédent
  • Mechanical thrombectomy with a novel stent retriever with multifunctional zones: Initial clinical experience with the NeVa™ thrombectomy device
  • M. Ribo, M. Requena, J. Macho, J. Zamarro, P. Machi, D. Hernandez, J. Blasco, A. Tomasello
| Article suivant Article suivant
  • Ventricular volumetry and free-water corrected diffusion tensor imaging of the anterior thalamic radiation in idiopathic normal pressure hydrocephalus
  • Asami Saito, Koji Kamagata, Ryo Ueda, Misaki Nakazawa, Christina Andica, Ryusuke Irie, Madoka Nakajima, Masakazu Miyajima, Masaaki Hori, Fumiaki Tanaka, Hajime Arai, Shigeki Aoki

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.