Médecine

Paramédical

Autres domaines


S'abonner

Le trabéculum : structure, fonction et implications cliniques. Une revue de la littérature - 15/08/20

The trabecular meshwork: Structure, function and clinical implications. A review of the littérature (French translation of the article)

Doi : 10.1016/j.jfo.2020.04.022 
J. Buffault a, , A. Labbé a, b, c, P. Hamard a, F. Brignole-Baudouin c, d, C. Baudouin a, b, c
a Service d’ophtalmologie, centre hospitalier national d’ophtalmologie des Quinze-Vingts, IHU FOReSIGHT, 28, rue de Charenton, 75012 Paris, France 
b Service d’ophtalmologie, hôpital Ambroise-Paré, AP–HP, 9, avenue Charles-de-Gaulle, 92100 Boulogne-Billancourt, France 
c Inserm, CNRS, institut de la vision, Sorbonne université, 17, rue Moreau, 75012 Paris, France 
d Service de biologie médicale, centre hospitalier national d’ophtalmologie des Quinze-Vingts, IHU FOReSIGHT, 28, rue de Charenton, 75012 Paris, France 

Auteur correspondant. Service 3, centre hospitalier national d’ophtalmologie des Quinze-Vingts, 28, rue de Charenton, 75012 Paris, France.Service 3, centre hospitalier national d’ophtalmologie des Quinze-Vingts28, rue de CharentonParis75012France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Saturday 15 August 2020
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Résumé

Le glaucome est une neuropathie optique cécitante dont le principal facteur de risque est l’augmentation de la pression intraoculaire (PIO). Le trabéculum, au niveau de l’angle iridocornéen, constitue la principale voie de drainage de l’humeur aqueuse (HA) hors de l’œil, et son dysfonctionnement est responsable d’une augmentation de la PIO. Le trabéculum est une structure tridimensionnelle fenêtrée complexe composée de cellules trabéculaires intriquées dans une organisation multicouche de matrice extracellulaire (MEC). L’objectif de cette revue de la littérature est de fournir un état des lieux de la connaissance sur le trabéculum et sa physiopathologie dans le glaucome. Ainsi, nous présenterons les bases anatomiques et cellulaires au centre de la régulation de la résistance à l’écoulement de l’HA, les mécanismes physiopathologiques d’altération trabéculaire impliqués dans les différents types de glaucomes, ainsi que les stratégies thérapeutiques existantes ou en développement ciblant le trabéculum.

Le texte complet de cet article est disponible en PDF.

Summary

Glaucoma is a blinding optic neuropathy, the main risk factor for which is increased intraocular pressure (IOP). The trabecular meshwork, located within the iridocorneal angle, is the main pathway for drainage of aqueous humor (AH) out of the eye, and its dysfunction is responsible for the IOP elevation. The trabecular meshwork is a complex, fenestrated, three-dimensional structure composed of trabecular meshwork cells (TMC) interdigitated into a multilayered organization within the extracellular matrix (ECM). The purpose of this literature review is to provide an overview of current understanding of the trabecular meshwork and its pathophysiology in glaucoma. Thus, we will present the main anatomical and cellular bases for the regulation of aqueous humor outflow resistance, the pathophysiological mechanisms involved in trabecular dysfunction in the various types of glaucoma, as well as current and future therapeutic strategies targeting the trabecular meshwork.

Le texte complet de cet article est disponible en PDF.

Mots clés : Trabéculum, Glaucome, Pression intraoculaire, Hypertonie oculaire, Angle iridocornéen, Cellules trabéculaires, Humeur aqueuse, Glaucome primitif à angle ouvert, Glaucome secondaire, Glaucome cortico-induit, Glaucome pigmentaire, Glaucome pseudoexfoliatif, Traitement hypotonisant, Trabéculoplastie, Chirurgie du glaucome

Keywords : Trabecular meshwork, Glaucoma, Intraocular pressure, Ocular hypertension, Iridocorneal angle, Trabecular meshwork cells, Aqueous humor, Primary open angle glaucoma, Secondary glaucoma, Steroid-induced glaucoma, Pigmentary glaucoma, Pseudoexfoliative glaucoma, Glaucoma medications, Trabeculoplasty, Glaucoma surgery


Plan


 Version française de l’article qui a été publié précédemment en anglais dans ce journal sous la référence : Buffault J, Labbé A, Hamard P, Brignole-Baudouin F, Baudouin C. The trabecular meshwork: Structure, function and clinical implications. A review of the litterature. Journal Français d’ophtalmologie 2020 ; https://doi.org/10.1016/j.jfo.2020.05.002.


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

;

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.