S'abonner

His bundle pacing procedure with limited radiation exposure - 25/09/20

Doi : 10.1016/j.acvdsp.2020.03.151 
C. Chaumont 1, , N. Auquier 2, E. Popescu 2, A. Milhem 3, A. Al Arnaout 3, G. Viart 1, A. Mirolo 1, A. Savoure 1, B. Godin 1, H. Eltchaninoff 1, 4, F. Anselme 1
1 Cardiology, Rouen University Hospital, Rouen 
2 Cardiology, Le Havre Hospital, Le Havre 
3 Cardiology, La Rochelle Hospital, La Rochelle 
4 Inserm U1096, Rouen University, Rouen, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction

His bundle pacing (HBP) is a physiological alternative to right ventricular pacing. Observational studies have demonstrated the feasibility of this technique. However, it is associated with longer procedure time and higher fluoroscopy exposure compared to standard pacemaker implantation.

Objective

We evaluated the possibility to guide the His Bundle (HB) lead placement using HB unipolar mapping only, in an attempt to reduce radiation exposure.

Method

From October to November 2019, all consecutive patients candidates for HBP in our institution underwent pacemaker implantation using mainly unipolar mapping of the His bundle for lead placement. All procedures were performed by a single trained operator. His bundle electrogram was mapped with the pacing lead and directly recorded on both EP recording system and Medtronic pacing analyzer.

Results

Fourteen patients were implanted according to this new approach. Seven patients had a dual chamber pacemaker implantation. Indication for pacemaker implantation was sinus node dysfunction in 2 patients, AV nodal ablation for non-controlled atrial arrhythmias in 5 patients and atrioventricular conduction disease in 7 patients. HBP was successful in all patients. His Bundle signal was detected with the SelectSecure pacing lead during all procedures. Selective HBP was obtained in 9 patients (64%) while non selective HBP occurred in 5 patients. The mean procedure duration was 44±8min. The overall procedure fluoroscopy duration, including the atrial lead implantation, was 30±13sec. The mean radiation exposure was 0.22±0.12Gy.cm2. The baseline QRS duration was 102±16ms and the paced QRS duration was 103±14ms. The mean HBP threshold at implant was 1.31±0.4V. There was no pericardial effusion and no pneumothorax.

Conclusion

His Bundle lead placement mainly using HB unipolar mapping was feasible and effective and was associated with very limited radiation exposure without compromising procedure duration.

Le texte complet de cet article est disponible en PDF.

Plan


© 2020  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 12 - N° 2-4

P. 263 - octobre 2020 Retour au numéro
Article précédent Article précédent
  • Regional repolarization shortening is more arrhythmogenic than regional conduction slowing in an ex vivo porcine experimental model
  • E. Renard, C. Michel, D. Benoist, V. Dubes, R. Walton, M. Martinez, O. Bernus
| Article suivant Article suivant
  • Identification by Whole Genome Sequencing of a New Gene Causing Hereditary Sinus Node and Atrioventricular Conduction Dysfunction
  • X. Le Guillou, P. Lindenbaum, E. Baron, A. Thollet, F. Kyndt, H. Le Marec, V. Probst, J.J. Schott, J.B. Gourraud, J. Barc

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.