Optimising micro computed tomography imaging of large animal and human hearts at high resolution - 25/09/20

Doi : 10.1016/j.acvdsp.2020.03.163 
N. Pallares Lupon 1, 2, , J. Duchâteau 1, 3, L. Yessad 1, 2, M. Constantin 1, 2, G. Ramlugun 1, 2, D. Gerneke 4, G. Sands 4, M.L. Trew 4, B. Smaill 4, M. Hocini 1, 3, M. Haissaguerre 1, 3, E. Vigmond 5, 6, B. Quesson 1, 2, O. Bernus 1, 2, R. Walton 1, 2
1 IHU Liryc - L’Institut de RYthmologie et Modélisation Cardiaque - Fondation Bordeaux Université 
2 CRCTB - Centre de Recherche Cardio-Thoracique de Bordeaux - Inserm, U1045 - Université de Bordeaux 
3 CHU Bordeaux, Bordeaux, France 
4 Auckland Bioengineering Institute, University of Auckland, Auckland, Nouvelle-Zélande 
5 Department of Electrical and Computer Engineering, University of Calgary, Calgary, Canada 
6 IMB - Institut de mathématiques de Bordeaux, Bordeaux, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction

Micro Computed tomography has emerged as a powerful imaging tool to study the micro-structure of cardiac tissue of small mammals. However, conventional techniques in whole organs of large mammals, is compromised due to the use of high molecular weight contrast agents and the relative thickness of samples.

Objective

To develop a tissue preparation method to optimize microCT imaging of whole hearts with sizes including those of humans.

Methods

Male pig hearts (N=5) were treated by: hydrated samples with conventional contrast agent (iodine, 0.5%) or dehydrated in ethanol and air-dried under hexamethyldisilazane (HMDS). Human hearts (N=3) were treated using air-drying method. Hearts were imaged at 21.7μm isotropic resolution by microCT (SkyScan 1276 Bruker). Images were quantified with Amira software using a 3D cylinder correlation technique.

Results

The X-ray attenuation of air-dried samples was better optimized for the bandwidth of the X-ray detector, indicated by reduced x-ray attenuation (pig 65%, human 55), compared to almost complete signal attenuation from hydrated samples (93%). Voxel intensity histograms showed two populations corresponding to the tissue and the background media and sample support structures. Yet, the separating minima of histogram intensities were always observed at lower intensities for air-dried hearts (Figure 1A) than hydrated hearts, increasing the dynamic range for tissue-specific signals (Figure 1B). Imaging air-dried pig or human hearts permitted a simple threshold-based segmentation to isolate microstructures of the heart, including vessels, myocardial fibers and Purkinje from the background (1C). Fiber orientation quantification could be performed directly on unfiltered images. Fiber orientation was validated against subsequent histology of the same samples.

Conclusion

Air drying with HMDS enables microCT imaging of human-sized hearts while preserving micro-structure and the identification of individual cardiac muscle fibers.

Le texte complet de cet article est disponible en PDF.

Plan


© 2020  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 12 - N° 2-4

P. 268-269 - octobre 2020 Retour au numéro
Article précédent Article précédent
  • Acute hexosamine pathway activation induces cardiac arrhythmia
  • M. Douard, F. Vaillant, E. Abell, E. White, P. Dos Santos, F. Brette

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.