S'abonner

Is patient-specific instrumentation more precise than conventional techniques and navigation in achieving planned correction in high tibial osteotomy? - 19/11/20

Doi : 10.1016/j.otsr.2020.08.009 
Nicolas Tardy a, , Camille Steltzlen b, Nicolas Bouguennec c, Jean-Loup Cartier d, Patrice Mertl e, Cécile Batailler f, Jean-Luc Hanouz g, Goulven Rochcongar h, Jean-Marie Fayard i
The

Francophone Arthroscopy Societyj

a Centre Ostéo-Articulaire des Cèdres, Clinique des Cèdres, 5, rue des Tropiques, 38130 Echirolles, France 
b Service de Chirurgie Orthopédique, Hôpital Mignot, 177, rue de Versailles, 78150 Le Chesnay, France 
c Clinique du Sport de Bordeaux-Mérignac, 2, rue Georges-Nègrevergne, 33700 Mérignac, France 
d Clinique Des Alpes Du Sud, 3, rue Antonin Coronat, 05000 Gap, France 
e Service de Chirurgie Orthopédique, CHU Amiens-Picardie Site Sud, 1, rond-point du Professeur Christian-Cabrol, 80054 Amiens cedex 1, France 
f Service de Chirurgie Orthopédique, Hôpital de la Croix-Rousse, 103, grande rue de la Croix Rousse, 69317 cedex 04 Lyon, France 
g Service d’Anesthésie Réanimation, CHU de Caen, avenue Côte De Nacre, 14033 Caen, France 
h Département de Chirurgie Orthopédique et Traumatologique, Niveau 11, Inserm U1075 COMETE “Mobilité: Attention, Orientation & Chronobiologie”, Université de Caen, Basse-Normandie, CHU de Caen, avenue de la Côte-de-Nacre, 14033 Caen cedex, France 
i Ramsay Générale de Santé, Hôpital Privé Jean-Mermoz, Centre Orthopédique Santy, 24, avenue Paul-Santy, 69008 Lyon, France 
j 15 rue Ampère, 92500 Rueil Malmaison, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Preoperative planning in high tibial osteotomy (HTO) is a critical step for achieving the desired correction and a clinically satisfactory outcome. Conventional radiography, navigation assistance and patient-specific instrumentation (PSI) are the 3 means of planning, but no prospective studies have compared precision between the 3. The aims of the present study were: (1) to analyze and compare correction precision between the 3 planning approaches at 1 year's follow-up; (2) to compare results to those reported in the literature; and (3) to analyze factors influencing the achievement of planned correction.

Hypothesis

The study hypothesis was that PSI provides more precise and reproducible planned correction than conventional methods or navigation.

Material and method

Between June 2017 and June 2018, a multicenter non-randomized prospective observational study was conducted in 11 centers. One hundred and twenty-six patients with Ahlbäck grade I, II or III idiopathic medial tibiofemoral osteoarthritis with stable knee were included and allocated to 3 preoperative planning groups: conventional (group 1), navigation (group 2) and PSI (group 3). Mean age at surgery was 51.2 years (range, 19-69 years; median, 53.2 years); 100 male, 26 female. Complete weight-bearing radiographic work-up was performed preoperatively and at 1 year's follow-up. The PSI group also underwent CT as part of guide production. Target angular correction and mechanical Hip-Knee-Ankle (HKA) axis were set preoperatively. The main endpoint was the difference between planned HKA and HKA at a minimum 12 months.

Results

Mean HKA difference was 1.1±3 in group 1, 2.1±2.6 in group 2 and 0.3±3.1 in group 3. Precision was better with PSI, but not significantly when comparing all 3 groups together. On pairwise intergroup comparison, there was a significant difference only between groups 2 and 3, in favor of PSI (P=0.011).

Discussion

None of the 3 techniques demonstrated superiority in achieving target correction at 1 year. The study hypothesis was thus not confirmed. All 3 techniques proved reliable and precise in HTO planning.

Level of evidence

III, prospective non-randomized comparative study.

Le texte complet de cet article est disponible en PDF.

Keywords : High tibial osteotomy, Navigation, PSI


Plan


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 106 - N° 8S

P. S231-S236 - décembre 2020 Retour au numéro
Article précédent Article précédent
  • Medium-term survival and clinical and radiological results in high tibial osteotomy: Factors for failure and comparison with unicompartmental arthroplasty
  • Nicolas Bouguennec, Guillaume Mergenthaler, Thomas Gicquel, Cyril Bryand, Elodie Nadau, Régis Pailhé, Jean Luc Hanouz, Jean Marie Fayard, Goulven Rochcongar, Francophone Arthroscopy Society
| Article suivant Article suivant
  • Does labral repair have a clinical benefit during arthroscopic treatment of femoro-acetabular impingement? Prospective multicentre study with 2-year follow-up
  • Olivier May, Karim Ouattara, Xavier Flecher, Michael Wettstein, Francophone Arthroscopy Society (SFA)

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.