Development of a simple in vitro artery model and an evaluation of the impact of pulsed flow on high-intensity focused ultrasound ablation - 23/11/20

Doi : 10.1016/j.irbm.2020.11.004 
Celia Cilleros a, b, Aurélien Dupré a, Jérémy Vincenot b, David Melodelima a,
a LabTAU, INSERM, Centre Leon Berard, Universite Lyon 1, Univ Lyon, F-69003, Lyon, France 
b EDAP TMS, 4 rue du dauphiné, Vaulx-en-Velin 69120, France 

Corresponding author.
Sous presse. Manuscrit accepté. Disponible en ligne depuis le Monday 23 November 2020
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Graphical abstract

Le texte complet de cet article est disponible en PDF.

Highlights

A simple in vitro model can mimic in vivo arteries.
This model reproduces both the geometrical and the mechanical local properties of an artery.
The effect of pulsed flow on thermal therapies can be evaluated using this model.

Le texte complet de cet article est disponible en PDF.

Abstract

Background

Many parameters have to be investigated before an optimal strategy for thermal therapies can be defined. Such studies are limited by the number of animals that may be included and by the difficulties in the use of isolated perfused organs. Realistic in vitro anthropomorphic vascular phantoms have been suggested and are based on the use of agar or silicone but not on biological tissues. More simply, biological and reliable models can be developed to mimic the behavior of arteries under perfusion.

Material and methods

Chicken esophagus was used since it reproduces both the anatomical and the mechanical local properties of a 5-mm-diameter artery. The esophagus was placed inside a bovine liver and connected to polyurethane tubes. The flow was driven using two pumps and a solenoid to mimic pulsed flow and the cardiac valve. The blood was mimicked using degassed water and 50-μm silica beads at a concentration of 40 mg/L. The Doppler signals used as a reference to validate the in vitro artery model were acquired during an animal study. Using a high-intensity focused ultrasound (HIFU) device, several HIFU lesions were created in vitro in liver samples with the artery mimic model placed at different depths.

Results

The waveforms of in vivo and in vitro Doppler signals had a cycle length of 1.09 s and 1.10 s, respectively, corresponding to 55 beats per minute (bpm). The average peak flow rate was 25.3 cm/s for in vivo waveforms and 27.8 cm/s for in vitro waveforms. The relative distension of the in vitro artery mimic (10%) was similar to that measured in pig mesenteric arteries and representative of human artery compliance. The dimensions of HIFU lesions were different depending on the location of the artery mimic.

Conclusions

A simple and reliable model of arteries is described. This model reproduced both the geometrical and the mechanical local properties of an artery. The flow profile, the flow rate and compliant behavior were found to be similar to those that can be recorded in vivo. This model can be used to evaluate the potential perfusion effects when developing devices for thermal therapies.

Le texte complet de cet article est disponible en PDF.

Plan


© 2020  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.