S'abonner

Effectiveness of two thermal activated orthodontic archwire sequences based on transition temperature range during alignment: A randomized non-controlled comparative study - 11/12/20

Doi : 10.1016/j.ortho.2020.09.006 
Júlio de Araújo Gurgel 1, , Célia Regina Maio Pinzan-Vercelino 2, Meire Coelho Ferreira 2, Daniella de Oliveira da Silva 2, Carlos Flores-Mir 3, Edson Albano Schwartz 4
1 São Paulo State University, Department of Speech-Language Pathology, Marília, São Paulo, Brazil 
2 Ceuma University, Department of Orthodontics, São Luís, Maranhão, Brazil 
3 University of Alberta, School of Dentistry, Department of Orthodontics, Edmonton, Alberta, Canada 
4 São Leopoldo Mandic Institute and Research Center Campinas, Department of Orthodontics, Campinas, São Paulo, Brazil 

Júlio de Araújo Gurgel, Av. Hygino Muzzi Filho, 737 Mirante CEP 17.525-900 Marília/SP, Brazil.Av. Hygino Muzzi Filho, 737 Mirante CEP Marília/SP17.525-900Brazil

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 2
Vidéos 0
Autres 0

Summary

Introduction

It has been suggested that heat-activated NiTi archwires (HANT) speed up crowding alleviation. HANT wires are available with different austenite finish temperatures.

Objective

The aim of the present study was to compare the effectiveness of two alignment sequences using thermally activated archwires with different austenite activation temperatures for the correction of mandibular anterior crowding.

Material and methods

The following NiTi archwire sequence was used for both groups: 0.012 in (conventional NiTi), 0.018 in (heat-activated NiTi archwires), 0.016×0.022 in (heat-activated NiTi archwires) and 0.019×0.025 in (conventional NiTi). The conventional NiTi used for both groups belongs to the same commercial brand. Two different austenite activation temperatures (35°C and 37°C) were used for the heat-activated archwires. The primary outcome was the degree of crowding correction measured on study models. The secondary outcome was crowding survival time over a six-month period. This RTC included fifty-four patients that were randomly allocated to the two different archwire sequences. A Mann-Whitney test was used to compare the groups regarding crowding alleviation. A survival curve was created using the Kaplan-Meier method to illustrate the reduction of crowding over time. A Mantel-Cox log-rank test was used to compare survival times (until correction of crowding).

Results

No differences in crowding alleviation were identified between both groups (log-rank test; P=0.77).

Conclusions

The two alignment sequences with different thermal activated archwires at 35°C and 37°C achieved similar clinical results during the correction of mandibular anterior crowding.

Le texte complet de cet article est disponible en PDF.

Keywords : Wire, Aligning archwire, Copper-nickel-titanium, Orthodontic wires, Transition phase, Temperature


Plan


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 18 - N° 4

P. 706-713 - décembre 2020 Retour au numéro
Article précédent Article précédent
  • Comparative assessment of the rate of orthodontic tooth movement in adolescent patients undergoing treatment by first bicuspid extraction and en mass retraction, associated with low-frequency mechanical vibrations in passive self-ligating and conventional brackets: A randomized controlled trial
  • Vaibhav Kumar, Puneet Batra, Karan Sharma, Sreevatsan Raghavan, Amit Srivastava
| Article suivant Article suivant
  • Digital assessment of direct and virtual indirect bonding of orthodontic brackets: A clinical prospective cross-sectional comparative investigation
  • Nearchos C. Panayi, Apostolos I. Tsolakis, Athanasios E. Athanasiou

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.