Wear and migration are not influenced by head size in a vitamin E-infused highly cross-linked polyethylene acetabular cup - 29/12/20

Doi : 10.1016/j.otsr.2020.03.030 
Simon Comtesse a, Arthur de Gast b, c, Philipp Rehbein d, Gary French e, Naeder Helmy f, Roland Becker g, Martin Dominkus h, i, Martin Beck j,
a Mathys Ltd Bettlach, Robert-Mathys Strasse 5, 2544 Bettlach, Switzerland 
b Diakonessenhuis Utrecht, Bosboomstraat 1, 3582 KE Utrecht, Netherlands 
c Clinical Orthopedic Research Centre midden-Nederland, Diakonessenhuis Zeist, Jagersingel 1, 3707 HL Zeist, Netherlands 
d St. Josefs-Hospital Wiesbaden, Beethovenstraße 20, 65189 Wiesbaden, Germany 
e Ormiston Hospital, 125, Ormiston Road, Flat Bush, 2016 Manukau, New Zealand 
f Bürgerspital Solothurn, Schöngrünstrasse 42, 4500 Solothurn, Switzerland 
g Städtisches Klinikum Brandenburg, Hochstraße. 29, 14770 Brandenburg, Germany 
h Orthopädisches Spital Speising, Speisinger Straße 109, 1130 Wien, Austria 
i Sigmund-Freud University, Campus Prater Freudplatz 1, 1020 Wien, Austria 
j Luzerner Kantonsspital, Spitalstrasse, 6000 Luzern, Switzerland 

Corresponding author at: Luzerner Kantonsspital, Spitalstrasse, 6000 Luzern, Switzerland.Luzerner KantonsspitalSpitalstrasseLuzern6000Switzerland
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Tuesday 29 December 2020
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

Aseptic loosening and periprosthetic osteolysis are frequent complications in total hip arthroplasty requiring revision surgery. Highly cross-linked polyethylene (HXLPE) implants have improved wear resistance, permitting larger femoral heads. However, such implants may experience surface cracking, mechanical failure, and oxidative damage. Vitamin E-infused HXLPE (VEPE) implants were therefore developed to reduce oxidation without compromising mechanical strength. We addressed the following questions: (1) Does femoral head size affect the midterm annual polyethylene wear rates of VEPE acetabular cups? (2) Does femoral head size affect the midterm migration rates of VEPE acetabular cups? (3) Are clinical outcomes affected by femoral head size?

Hypothesis

Annual wear rate, migration rate, and clinical outcomes of VEPE acetabular cups are independent of femoral head size.

Patients and methods

This was a prospective, multicentre, observational study of patients that underwent total hip arthroplasty. Hips were grouped according to the size of femoral head implanted (28 mm, 32 mm, and 36 mm). We determined annual wear rate and migration rate of VEPE acetabular cups using the Einzel-Bild-Röntgen-Analyse software. Clinically, we assessed the Harris Hip Score and visual analog score for pain and satisfaction.

Results

We followed 253 patients (267 hips) for a mean of 55.0±20.6 months in the 28 mm, 46.2±21.4 months in the 32 mm, and 43.8±22.6 months in the 36 mm group. The annual wear rate was 0.025 mm per year from 1 year to the last follow-up and remained similar between the groups (p>0.05). Also, mean two-dimensional migration rates did not exceed 0.05 mm from 2 years to the last follow-up and remained similar between the groups (p=0.355). Finally, clinical outcomes also did not differ between the groups (p>0.05). Two patients required revision surgery.

Discussion

Femoral head size did not influence midterm annual wear rate, migration rate, and clinical outcomes of VEPE acetabular cups. Furthermore, wear and cup migration rates were below the reported values leading to osteolysis and aseptic loosening. Nevertheless, studies with extended follow-up periods will be necessary to confirm these results in the long term.

Level of evidence

IV.

Le texte complet de cet article est disponible en PDF.

Keywords : Pressfit cup, EBRA, VEPE, Wear, Migration


Plan


© 2020  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.