S'abonner

Predictive factors of inappropriate therapies in subcutaneous implantable cardioverter defibrillators - 09/01/21

Doi : 10.1016/j.acvdsp.2020.10.211 
M. Ben Kilani , P. Jacon, A. Carabelli, S. Venier, D. Sonou, M. Jabeur, P. Defaye
 Grenoble-Alpes University Hospital, Grenoble, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction

The subcutaneous implantable cardioverter defibrillator (S-ICD) has been considered as a comparable alternative to transvenous ICD in a wide array of patients (pts) without pacing indication. Recent data have reported high rates of inappropriate (inap) therapies with S-ICD, mostly due to T wave or noise oversensing.

Purpose

Our aim was to assess the predictive factors of inap therapies over a mid-term follow-up (FU) period after SICD implantation.

Methods

All pts implanted with an S-ICD and a FU above 6 months were included in a cross-sectional monocentric study. Data from preoperative screening with a thorough ECG study (amplitude of QRS complex, T wave and QRS:T ratio in leads I, II and III) has been collected. Pts were followed by remote monitoring.

Results

One hundred and twenty-four pts (50±14 years old, male 84%) were included. Indications were: primary 73% and secondary prevention 27% (ischemic cardiopathy 39%; hypertrophic 8%; dilated 36%; channelopathy 2%). During a mean FU of 25±16 months, 29 pts (23%) experienced at least one therapy: 15 pts with appropriate (12%) and 15 pts with inap shocks (12%). A total of 22 inap shocks have been observed after a mean FU period of 15±18 months (1.5±1 inap shock per pt, several shocks for 4 pts). Causes were: supraventricular arrhythmias (33%), T wave (20%) and noise (53%) oversensing. The number of eligible vectors during preoperative screening was correlated with the occurrence of inap shocks (−0.23; P<0.05). ECG criteria measured in lead I were significantly correlated with inap therapies: QRS and T wave amplitude, respectively −0.23 and 0.3 (P<0.01), and the QRS:T ratio in lead I (−0.34; P<0.01). Of note, the untreated events related to T wave or noise oversensing during the FU were correlated with inap shocks (0.32; P<0.01) (Fig. 1).

Conclusion

Inap therapies remain frequent with S-ICD. Preoperative screening (number of eligible vectors) and ECG data may be taken into consideration to identify patients at high risk for inap shocks.

Le texte complet de cet article est disponible en PDF.

Plan


© 2020  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 13 - N° 1

P. 93-94 - janvier 2021 Retour au numéro
Article précédent Article précédent
  • Can echocardiography predict the diagnosis of obstructive sleep apnea or its severity in a Tunisian population with atrial fibrillation?
  • M. Ben Halima, K. Sammoud, B. Rekik, S. Boudiche, F. Mghaieth, A. Farhati, N. Larbi, S. Ouali, J. Ben Amar, H. Aouina, M.S. Mourali
| Article suivant Article suivant
  • His Bundle pacing procedure with limited X-Ray exposure
  • C. Chaumont, A. Mirolo, A. Savoure, B. Godin, H. Eltchaninoff, F. Anselme

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.