Diagnostic performance of pulmonary ultrasonography and a clinical score for the evaluation of fluid overload in haemodialysis patients - 04/02/21

Doi : 10.1016/j.nephro.2020.10.008 
Mickaël Bobot a, c, , Laurent Zieleskiewicz b, c, Noémie Jourde-Chiche a, c, Clarissa Von Kotze a, Manon Ebersolt a, Bertrand Dussol a, Marion Sallée a, c, Sophie Chopinet d, Yvon Berland a, Philippe Brunet a, c, Thomas Robert a
a Aix-Marseille University, Department of Nephrology, AP–HM, La Conception Hospital, 147, boulevard Baille, 13005 Marseille, France 
b Aix-Marseille University, Department of Anaesthesiology and Intensive Care, AP–HM, Nord Hospital, Marseille, France 
c C2VN Laboratory, Inserm 1263, INRAE 1260, Aix-Marseille University, Marseille, France 
d Aix-Marseille University, Department Digestive Surgery, AP–HM, La Timone Hospital, Marseille, France 

Corresponding author at: Aix-Marseille University, Department of Nephrology, AP–HM, La Conception Hospital, 147, boulevard Baille, 13005 Marseille, France.Aix-Marseille University, Department of Nephrology, AP–HM, La Conception Hospital147, boulevard BailleMarseille13005France

Abstract

Introduction

There is no feasible benchmark in daily routine to estimate the hydration status of haemodialysis patients, which is essential to their management.

Objective

We performed a study in haemodialysis patients to assess the diagnostic performance of pulmonary ultrasound and clinical examination for the evaluation of fluid overload using transthoracic echocardiography as a gold standard.

Methods

Thirty-one patients receiving chronic haemodialysis patients were included. Evaluation of hydration status was assessed weekly before haemodialysis sessions using clinical and Echo Comet Score from pulmonary ultrasound and transthoracic echocardiography (reference method).

Results

Five patients had a transthoracic echocardiography overload. Compared with transthoracic echocardiography, the diagnostic performance of the clinical overload score has a sensitivity of 100%, a specificity of 77%, a positive predictive value of 50% and a negative predictive value of 100% with a κ of 0.79. Only orthopnoea (P=0.008), jugular turgor (P=0.005) and hepatic-jugular reflux (P=0.008) were significantly associated with transthoracic echocardiography overload diagnosis. The diagnostic performance of Echo Comet Score by pulmonary ultrasound has a sensitivity of 80%, a specificity of 58%, a positive predictive value of 26% and a negative predictive value of 94%. Ten patients (32.3%) had an increase of extravascular pulmonary water without evidence of transthoracic echocardiography or clinical overload.

Conclusions

Our clinical score has a convincing diagnostic performance compared to transthoracic echocardiography and could be easily used in daily clinical routine to adjust dry weight. The evaluation of the overload using pulmonary ultrasound seems poorly correlated with the overload evaluated by transthoracic echocardiography. Extravascular pulmonary water undetected by clinical examination and transthoracic echocardiography remains a parameter that requires further investigation.

Le texte complet de cet article est disponible en PDF.

Keywords : Echocardiography, Fluid overload, Haemodialysis, Hydration status, Lung ultrasound


Plan


© 2020  Société francophone de néphrologie, dialyse et transplantation. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 17 - N° 1

P. 42-49 - février 2021 Retour au numéro
Article précédent Article précédent
  • The application of neutrophil gelatin-related lipid delivery protein in evaluation of renal function, nutrition, anemia and inflammation in patients with CKD
  • Zhoupeng Gu, Yan Huang, Fengjie Yang, Shiqi Tang, Juan Sun, Tianru Chen, Fang Liu, Hong Wu, Jianwen Wang
| Article suivant Article suivant
  • Anévrisme veineux juxta-anastomotique d’une fistule au niveau de la tabatière anatomique : une localisation atypique
  • Hajar El Bhali, Othman Zahdi, Badr Bensaid, Samir El Khloufi, Yasser Sefiani, Abbes El Mesnaoui, Brahim Lekehal

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.