S'abonner

Shear bond strength of APC Plus adhesive coated appliance system to enamel in wet and dry conditions: An in vitro study - 23/02/21

Doi : 10.1016/j.ortho.2021.01.001 
Zaid Nadhim Jawad Safar Ali 1, Allahyar Geramy 2, Soolmaz Heidari 3, Hannaneh Ghadirian 2,
1 Nasser Al-musoay for Dental Specialization Center, Department of Orthodontics, Department of Alnajaf Health and Medical Services, Al-shahied Najaf, Iraq 
2 Tehran University of Medical Sciences, Faculty of Dentistry, Department of Orthodontics, Tehran, Iran 
3 Qazvin University of Medical Sciences, Dental Caries Prevention Research Center, Department of Operative Dentistry, Qazvin, Iran 

Hannaneh Ghadirian, Tehran University of Medical Sciences, Faculty of Dentistry, Department of Orthodontics, Tehran, Iran.Tehran University of Medical Sciences, Faculty of Dentistry, Department of OrthodonticsTehranIran

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 7
Iconographies 2
Vidéos 0
Autres 0

Highlights

This study assessed the SBS provided by APC Plus adhesive coated appliance system in wet and dry conditions when used in combination with hydrophilic MIP.
The results revealed that the SBS in wet condition was significantly lower than that in dry condition.
In both groups, the provided SBS exceeded the clinically acceptable minimal threshold of 6 to 8MPa.

Le texte complet de cet article est disponible en PDF.

Summary

Objective

It is claimed that a hydrophilic primer, called the moisture insensitive primer (MIP), can be used with both dry and wet enamel surfaces. This study sought to assess the shear bond strength (SBS) of APC Plus adhesive coated appliance system to enamel using MIP in wet and dry conditions.

Materials and Methods

This in vitro experimental study evaluated 24 extracted maxillary premolars with intact buccal enamel. The teeth were randomly divided into two groups (n=12), and APC Plus premolar brackets were bonded to their buccal surface using moisture insensitive primer (MIP) under wet and dry enamel conditions. The SBS values were measured by a universal testing machine. The adhesive remnant index (ARI) score was also determined under a stereomicroscope. Data were analyzed using t-test and Mann–Whitney test at P<0.05 level of significance.

Results

The SBS in wet condition was significantly lower than that in dry condition (mean value of 18.37MPa versus 25.5MPa, P<0.001). The two groups had no significant difference regarding the ARI scores (P>0.05). However, in both groups, less adhesive was left on the tooth surface. This suggests that bond failure occurred at the adhesive-enamel interface.

Conclusions

APC Plus adhesive coated appliance system in combination with hydrophilic MIP can be effective in clinical conditions with high risk of moisture contamination.

Le texte complet de cet article est disponible en PDF.

Keywords : Shear Strength, Orthodontic Brackets, APC Plus, Moisture-insensitive primer, Dental Enamel bonding, Dry, Wet conditions


Plan


© 2021  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 19 - N° 1

P. 130-136 - mars 2021 Retour au numéro
Article précédent Article précédent
  • Effect of high concentration nano-hydroxyapatite serum on shear bond strength of metal brackets following three different enamel surface preparation methods: An in vitro study
  • Neda Babanouri, Ali Reza Ghafoori, Shabnam Ajami, Arezoo Mahdian
| Article suivant Article suivant
  • Evaluation of the dimensional accuracy of thermoformed appliances taken from 3D printed models with varied shell thicknesses: An in vitro study
  • Keri B. Kenning, Dane C. Risinger, Jeryl D. English, Benjamin E. Cozad, Lacey M. Harris, Joe C. Ontiveros, F. Kurtis Kasper

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.