S'abonner

A novel, automated, quantification of abnormal lung parenchyma in patients with COVID-19 infection: Initial description of feasibility and association with clinical outcome - 24/03/21

Doi : 10.1016/j.accpm.2020.10.014 
Eric Noll a, , Luc Soler d, e, Mickael Ohana f, Pierre-Olivier Ludes a, c, Julien Pottecher a, c, Elliott Bennett-Guerrero g, Francis Veillon h, Bernard Goichot i, Francis Schneider j, Nicolas Meyer k, Pierre Diemunsch a, b, c
a Department of Anesthesiology and Intensive Care, Hautepierre Hospital, Strasbourg University Hospital, France 
b Institut Hospitalo-Universitaire “Image-Guided Surgery”, Strasbourg University Hospital, Strasbourg, France 
c Equipe d’Accueil 3072, Medical School, Strasbourg University, Strasbourg, France 
d Digestive and Endocrine Surgery Department, Nouvel Hôpital Civil, Strasbourg, France 
e Visible Patient, Strasbourg, France 
f Department of Radiology, Nouvel Hôpital Civil, Strasbourg University Hospital, France 
g Department of Anesthesiology, Stony Brook Medicine, New-York, USA 
h Department of Radiology, Hautepierre Hospital, Strasbourg University Hospital, France 
i Department of Internal Medicine, Hautepierre Hospital, Strasbourg University Hospital, France 
j Médecine Intensive-Réanimation, Hautepierre Hospital, Strasbourg University Hospital, Strasbourg, France 
k Department of Biostatistics, Strasbourg University Hospital, France 

Corresponding author at: Department of Anesthesiology and Intensive Care, Hautepierre Hospital, Strasbourg, France.Department of Anesthesiology and Intensive CareHautepierre HospitalStrasbourgFrance

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Objective

Ground-glass opacities are the most frequent radiologic features of COVID-19 patients. We aimed to determine the feasibility of automated lung volume measurements, including ground-glass volumes, on the CT of suspected COVID-19 patients. Our goal was to create an automated and quantitative measure of ground-glass opacities from lung CT images that could be used clinically for diagnosis, triage and research.

Design

Single centre, retrospective, observational study.

Measurements

Demographic data, respiratory support treatment (synthetised in the maximal respiratory severity score) and CT-images were collected. Volume of abnormal lung parenchyma was measured with conventional semi-automatic software and with a novel automated algorithm based on voxels X-Ray attenuation. We looked for the relationship between the automated and semi-automated evaluations. The association between the ground-glass opacities volume and the maximal respiratory severity score was assessed.

Main results

Thirty-seven patients were included in the main outcome analysis. The mean duration of automated and semi-automated volume measurement process were 15 (2) and 93 (41) min, respectively (p=8.05*10−8). The intraclass correlation coefficient between the semi-automated and automated measurement of ground-glass opacities and restricted normally aerated lung were both superior to 0.99. The association between the automated measured lung volume and the maximal clinical severity score was statistically significant for the restricted normally aerated (p=0.0097, effect-size: −385mL) volumes and for the ratio of ground-glass opacities/restricted normally aerated volumes (p=0.027, effect-size: 3.3).

Conclusion

The feasibility and preliminary validity of automated impaired lung volume measurements in a high-density COVID-19 cluster was confirmed by our results.

Le texte complet de cet article est disponible en PDF.

Keywords : COVID-19, ARDS, CT-scan, Triage, Severity assessment, Infectious disease


Plan


© 2020  Société française d'anesthésie et de réanimation (Sfar). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 40 - N° 1

Article 100780- février 2021 Retour au numéro
Article précédent Article précédent
  • Association between red blood cell distribution width and mortality of COVID-19 patients
  • Leonardo Lorente, María M. Martín, Mónica Argueso, Jordi Solé-Violán, Alina Perez, José Alberto Marcos Y Ramos, Luis Ramos-Gómez, Sergio López, Andrés Franco, Agustín F. González-Rivero, María Martín, Verónica Gonzalez, Julia Alcoba-Flórez, Miguel Ángel Rodriguez, Marta Riaño-Ruiz, Juan Guillermo O Campo, Lourdes González, Tamara Cantera, Raquel Ortiz-López, Nazario Ojeda, Aurelio Rodríguez-Pérez, Casimira Domínguez, Alejandro Jiménez
| Article suivant Article suivant
  • Collective aeromedical transport of COVID-19 critically ill patients in Europe: A retrospective study
  • Jean Turc, Henri-Louis Dupré, Madeleine Beaussac, Sophie Murris, Lionel Koch, Raphael Paris, Julia Di Filippo, Berangère Distinguin, Violaine Muller, Mathieu Boutonnet

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.