S'abonner

Minimising radiation exposure to the surgeon in minimally invasive spine surgeries: A systematic review of 15 studies - 02/04/21

Doi : 10.1016/j.otsr.2020.102795 
Shahswar Arif a, Zarina Brady a, , Yavor Enchev a, b, Nikolay Peev c, Elitsa Encheva a
a Medical university of Varna, ul. “Professor Marin Drinov” 55, 9002 Center Varna, Bulgaria 
b Department of neurosurgery, medical university of Varna, university hospital “St. Marina”, Varna, Bulgaria 
c Department of neurosurgery, Royal Victoria hospital, Belfast health and social care trust, Belfast, Northern Ireland, United Kingdom 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 02 April 2021
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

Intraoperative imaging in minimally invasive spinal surgeries is associated with significant radiation exposure to surgeons, which overtime can lead to serious health hazards including malignancy. In this study, the authors conducted a systematic review to evaluate the efficacy of navigation assisted fluoroscopy methods on radiation exposure to the surgeon in minimally invasive spine surgeries, percutaneous endoscopic lumbar discectomy/percutaneous endoscopic transforaminal discectomy versus minimally invasive spine transforaminal lumbar interbody fusion (PELD/PETD versus MIS-TLIF).

Methods

A systematic literature search was conducted using PUBMED/MEDLINE on 20th July, 2020. Inclusion criteria were applied according to study design, surgical technique, spinal region, and language. Data extracted included lumbar segment, average operation time (min), fluoroscopic time (s), and radiation dose (μSV), efficacy of modified navigation versus conventional techniques; on reducing operation, fluoroscopy times and effective radiation dose.

Results

Fifteen studies (ten prospectives, and five retrospectives) were included for quantitative analysis. PELD recorded a shorter operation time (by 126.3min, p<0.001) and fluoroscopic time (by 22.9s, p=0.3) than MIS-TLIF. The highest radiation dose/case (μSV) for both techniques were recorded at the surgeon's: finger, chest, neck and eye. The effective dose for MIS-TLIF was 30μSV higher than PELD. Modified navigation techniques recorded a shorter operation time (by 15.9min, p=0.3); fluoroscopy time (by 289.8s, p=0.3); effective radiation dose (by 169.5μSV, p=0.3) than conventional fluoroscopy methods.

Discussion

This systematic literature review showed that although navigation assisted fluoroscopy techniques are superior to conventional methods in minimising radiation exposure, lack of statistical significance warrants future randomised controlled trials, to solidify their efficacy in reducing radiation related hazards.

Le texte complet de cet article est disponible en PDF.

Keywords : Radiation exposure, Navigation assisted, Minimally invasive spine surgeries, PELD, MIS-TLIF


Plan


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.