S'abonner

Diagnostic accuracy of the BJI InoPlex™ (Diaxonhit) immunoassay on blood samples for periprosthetic joint infection in complex microbiological situations. Preliminary results of 24 cases in a French Reference Center for Complex Bone and Joint Infection (CRIOAC) - 07/04/21

Doi : 10.1016/j.otsr.2021.102909 
Julien Dartus a, b, c, , Pierre Martinot a, b, c, Jean-Thomas Leclerc b, c, d, Eric Senneville a, b, e, Frédéric Wallet a, b, f, Sophie Putman a, b, c, Henri Migaud a, b, c, Caroline Loiez a, b, f
a University Lille, CHU de Lille, ULR 4490, département universitaire de chirurgie orthopédique et traumatologique, 59000 Lille, France 
b CRIOAC, centre de référence pour le traitement des infections ostéo-articulaires complexes Lille-Tourcoing, rue Emile-Laine, 59037 Lille, France 
c CHU de Lille, service de chirurgie orthopédique, hôpital Roger-Salengro, 2, avenue Oscar-Lambret, 59000 Lille, France 
d Service de chirurgie orthopédique, CHU de Québec–université Laval, 2325, rue de l'Université, Québec, QC G1V 0A6, Canada 
e Service de maladie infectieuses et du voyageur, CH Dron, rue du Président-Coty, 59208 Tourcoing, France 
f CHU de Lille, service de bactériologie-hygiène, centre de biologie-pathologie, 59000 Lille, France 

Corresponding author at:CHU de Lille, service de chirurgie orthopédique, hôpital Roger-Salengro, 2, avenue Oscar-Lambret, 59000 Lille, France.CHU de Lille, service de chirurgie orthopédique, hôpital Roger-Salengro2, avenue Oscar-LambretLille59000France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Wednesday 07 April 2021
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

While joint aspiration is the benchmark for diagnosing periprosthetic joint infections (PJI), the results can be flawed because certain bacteria are difficult to culture, the patient is on concurrent antibiotic therapy or in some cases, repeated joint aspirations confer conflicting results. The BJI InoPlex™ (Diaxonhit) is a multiplex ELISA (Enzyme Linked Immunosorbent Assay) that measures the immune response (presence of specific IgG) to certain bacterial species from three families: Staphylococcus (8 antigens) epidermidis, aureus and lugdunensis, Streptococcus B (4 antigens) and Cutibacterium acnes (4 antigens). This assay is done with peripherally collected blood. However, there are few published studies about this assay, especially if the microbiological diagnosis is in doubt in cases of suspected chronic PJI. This led us to conduct a retrospective study in a French tertiary care center to determine 1) the sensitivity and specificity of the BJI InoPlex™, 2) its positive (PPV) and negative predictive value (NPV) and 3) what causes diagnostic errors.

Hypothesis

The BJI InoPlex has a sensitivity/specificity and PPV/NPV above 75%.

Materials and methods

The BJI InoPlex was used 24 times on 24 patients between January 2016 and January 2017 in scenarios where the microbiological diagnosis was difficult: 1 with on-going antibiotic therapy, 13 conflicting repeat joint aspirations, 10 negative cultures with history of infection and/or clinical evidence of a PJI. The series consisted of 11 hip arthroplasty and 13 knee arthroplasty cases. The results of the BJI InoPlex test were compared to the MusculoSkeletal Infection Society (MSIS) the criteria for a joint infection.

Results

For the bacterial species covered by the test, the sensitivity of the BJI InoPlex for diagnosing a chronic PJI based on the 2018 MSIS criteria was 50%, the specificity was 56%, the PPV was 36% and the NPV was 69%.

Discussion

While innovative, minimally invasive, and rapid (results in a few hours), the BJI InoPlex does not provide an effective diagnosis of chronic PJI in complex microbiological situations. In this study, we used the test in the most difficult situations possible and on a small number of patients, which may explain why the results were not as good as in other studies. Its current performance and cost mean there is no role for it in our algorithm for treating patients with a suspected PJI, contrary to other biomarkers. Its spectrum must include other bacterial strains involved in chronic PJI. Knowledge of the specific infectious agent increases its diagnostic value, it could be used to monitor the outcome of a PJI, although other studies would be needed to support this use.

Level of evidence

IV–Retrospective diagnostic study.

Le texte complet de cet article est disponible en PDF.

Keywords : Periprosthetic joint infection, BJI InoPlex, Diagnosis, Joint aspiration, Immunoassay, Biomarkers


Plan


© 2021  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.