S'abonner

Single-source dual energy CT to assess myocardial extracellular volume fraction in aortic stenosis before transcatheter aortic valve implantation (TAVI) - 24/04/21

Doi : 10.1016/j.diii.2021.03.003 
Benjamin Dubourg a, b, , Jean-Nicolas Dacher a, b, Eric Durand b, c, Jérôme Caudron a, b, Fabrice Bauer b, c, Michael Bubenheim d, Hélène Eltchaninoff b, c, Jean-Michel Serfaty e
a Department of Radiology, University Hospital of Rouen, 76031 Rouen, France 
b UNIROUEN, Inserm U1096 EnVI & FHU REMOD-VHF, Normandie Université, Rouen, France 
c Department of Cardiology, University Hospital of Rouen, 76031 Rouen, France 
d Department of Biostatistics, University Hospital of Rouen, 76031 Rouen, France 
e Department of Radiology, Institut du Thorax, INSERM, CNRS, UNIV Nantes, CHU Nantes, 44000 Nantes, France 

Corresponding author. Department of Radiology, University Hospital of Rouen, 76031 Rouen, France.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Saturday 24 April 2021
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Highlights

Iodine maps using dual energy CT can be used to measure directly myocardial extra cellular volume (ECV).
Myocardial ECV measured by dual-energy CT strongly correlates with MRI measurements.
Myocardial ECV is increased in patients with severe aortic stenosis compared to normal values.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

To assess myocardial extracellular volume fraction (ECV) measurement provided by a single-source dual-energy computed tomography (SSDE-CT) acquisition added at the end of a routine CT examination before transcatether aortic valve implantation (TAVI) compared to cardiac magnetic resonance imaging (MRI).

Materials and methods

Twenty-one patients (10 men, 11 women; mean age, 86±4.9 years [SD]; age range: 71–92 years) with severe aortic stenosis underwent standard pre-TAVI CT with additional cardiac SSDE-CT acquisition 7minutes after intravenous administration of iodinated contrast material and myocardial MRI including pre- and post-contrast T1-maps. Myocardial ECV and standard deviation (σECV) were calculated in the 16-segments model. ECV provided by SSDE-CT was compared to ECV provided by MRI, which served as the reference. Analyses were performed on a per-segment basis and on a per-patient involving the mean value of the 16-segments.

Results

ECV was slightly overestimated by SSDE-CT (29.9±4.6 [SD] %; range: 20.9%–48.3%) compared to MRI (29.1±3.9 [SD] %; range: 22.0%–50.7%) (P<0.0001) with a bias and limits of agreement of +2.3% (95%CI: −16.1%–+20.6%) and +2.5% (95%CI: −2.1%–+7.1%) for per-segment and per-patient-analyses, respectively. Good (r=0.81 for per-segment-analysis) to excellent (r=0.97 for per-patient-analysis) linear relationships (both P<0.0001) were obtained. The σECV was significantly higher at SSDE-CT (P<0.0001). Additional radiation dose from CT was 1.89±0.38 (SD) mSv (range: 1.48–2.47 mSv).

Conclusion

A single additional SSDE-CT acquisition added at the end of a standard pre-TAVI CT protocol can provide ECV measurement with good to excellent linear relationship with MRI.

Le texte complet de cet article est disponible en PDF.

Keywords : Computed tomography, Aortic stenosis, Transcatheter aortic valve implantation (TAVI), Magnetic resonance imaging (MRI), Contrast agent

Abbreviations : AHA, ASIR, BMI, CI, CT, CTA, CTDIvol, DE-CT, DLP, DSDE-CT, ECV, FOV, HU, ICA, LGE, MD, MRI, PSIR, ROI, SD, SSDE-CT, TAVI


Plan


© 2021  Société française de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.