S'abonner

The influence of the number of holes in the open wedge high tibial osteotomy on knee biomechanics using finite element analysis - 20/05/21

Doi : 10.1016/j.otsr.2021.102884 
Kyoung-Tak Kang a, Yong-Gon Koh b, Jin-Ah Lee a, Jae Jung Lee c, Paul Shinil Kim d, Sae Kwang Kwon c,
a Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, 03722 Seoul, Republic of Korea 
b Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, 06698 Seocho-gu, Seoul, Republic of Korea 
c Department of Orthopaedic Surgery, Yonsei BonSarang Hospital, 706 Buil-ro, Bucheon-si, Gyeonggi-do, Republic of Korea 
d Department of orthopaedic surgery, The bonehospital, 67, Dongjak-daero, Dongjak-gu, 07014 Seoul, Republic of Korea 

Corresponding author. Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, 06698 Seocho-gu, Seoul, Republic of Korea.Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital10 Hyoryeong-roSeocho-gu, Seoul06698Republic of Korea

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

The most significant differences of high tibial osteotomy (HTO) were found in terms of plate length, and this was related to number of holes distal region of the plate below wedge. The purpose of this study is to evaluate the biomechanical effects of three different designs medial opening wedge plates.

Hypothesis

The design of the HTO plate influenced the outcome of the biomechanics.

Methods

The HTO model was simulated using finite element (FE) model. This FE investigation included three types of loading conditions corresponding to the loads used in the experimental study for model validation and model predictions for clinically relevant loading scenarios. The average stress and contact stress were evaluated.

Results

The highest average stress was observed in the TomoFix. Conversely, the stress on the bone declined in the order of Puddu, Maxi and TomoFix plates. The micromotion in the wedge displayed a similar trend to the stress on bone. The highest and lowest contact stresses on the medial meniscus were observed in the Puddu and TomoFix plate, respectively. However, an opposite trend was observed in the lateral meniscus. The contact stress on medial and lateral menisci decreased and increased, respectively, in all three different plates when compared to those in the intact model.

Discussion

The TomoFix plate exhibited the highest stability relative to the micromotions of the wedge. However, in terms of the stress on the bone and plates, a stress-shielding effect could exist in the TomoFix plate. Additionally, the contact stress on the articular surface suggested that a complicated relationship could exist with respect to the plate design.

Level of evidence

IV.

Le texte complet de cet article est disponible en PDF.

Keywords : High tibial osteotomy, HTO plate design, Finite element analysis

Abbreviations : ATT, CT, MRI, OA, PTT, 3D


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 107 - N° 4

Article 102884- juin 2021 Retour au numéro
Article précédent Article précédent
  • Osteotomy around the knee is planned toward an anatomical bone correction in less than half of patients
  • Grégoire Micicoi, Francesco Grasso, Kristian Kley, Henri Favreau, Raghbir Khakha, Matthieu Ehlinger, Christophe Jacquet, Matthieu Ollivier
| Article suivant Article suivant
  • The patellofemoral joint does not deteriorate clinically after open-wedge high tibial osteotomy
  • Hee-June Kim, Ji-Yeon Shin, Hyun-Joo Lee, Kyeong-Hyeon Park, Chul-Hee Jung, Hee-Soo Kyung

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.