Comparative evaluation of displacement and stress distribution pattern during maxillary arch distalization with Infra Zygomatic Screw- A three dimensional finite element study - 31/05/21

Doi : 10.1016/j.ortho.2021.03.006 
Junaid Khan 1, , Manish Goyal 1, Mukesh Kumar 1, Ashish Kushwah 2, Amandeep Kaur 1, Madhur Sharma 1
1 Department of Orthodontics and Dentofacial Orthopaedics, Teerthanker Mahaveer Dental College, Moradabad, Uttar Pradesh, India 
2 Department of Orthodontics and Dentofacial Orthopaedics, Institute of Dental Education & Advanced Studies, Gwalior, Madhya Pradesh, India 

Junaid Khan, Department of Orthodontics and Dentofacial Orthopaedics, Teerthanker Mahaveer Dental College, B-270, Block-B, Sector-105, 201304 Noida, GB Nagar, Uttar Pradesh, India.Department of Orthodontics and Dentofacial Orthopaedics, Teerthanker Mahaveer Dental CollegeB-270, Block-B, Sector-105Noida, GB Nagar, Uttar Pradesh201304India

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 10
Iconographies 8
Vidéos 0
Autres 0

Summary

Objective

This study aimed to evaluate and compare the distribution of stress and displacement of teeth during maxillary arch distalization with IZC (Infra zygomatic crest) screw with two maxillary positions and different lever arm heights.

Settings and Design

Six three-dimensional finite element models of the maxillary arch were constructed with third molars extracted. Models 1, 2 and 3: IZC 6 (mesial to mesiobuccal root of first molar, 6) with 0mm, 4mm and 8mm lever arm height; Models 4, 5 and 6: IZC 7 (mesial to mesiobuccal root of second molar, 7) with 0mm, 4mm and 8mm, respectively.

Material and methods

MBT preadjusted Brackets (slot size 0.022×0.028") were placed over the clinical crown's centre with 0.019×0.025" stainless steel archwire on all six models. Retraction force of 4N was applied with different combinations of IZC screws and lever arm bilaterally using Nickel-Titanium (NiTi) closed coil spring. Then, evaluation of stress distribution, von Mises stress and maxillary teeth displacement were performed using ANSYS 12.1 software.

Results

In this study, maximum von Mises stress in alveolar bone (cortical bone) was observed in Model 4 (107.79MPa) at the screw fixation site that was within the optimum limit (135MPa). Different extents of displacements like labiolingual tipping of crown, labiolingual tipping of root, extrusion and intrusion were noticed. The models with 0mm and 4mm lever arm height (models1, 2, 4 and 5) showed more controlled crown and root movements in comparison to 8mm long lever arm models (models 3 and 6). In model 5, a maximum distal movement compared to all other five models was observed.

Conclusions

IZC 7 position showed the most favourable results (maximum distalization) with the lever arm height of 4mm. Therefore, the nearer the force to the centre of resistance of the tooth, the greater is distalization. Stresses on the IZC screw decreases when lever arm height increases, in all the models.

Le texte complet de cet article est disponible en PDF.

Keywords : Distalization, Finite element models, Infrazygomatic screws, Von Mises stress, Centre of resistance


Plan


© 2021  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 19 - N° 2

P. 291-300 - juin 2021 Retour au numéro
Article précédent Article précédent
  • Comparative study of effect of different lever arm positions and lengths on transverse and vertical bowing in lingual orthodontics – An FEM study
  • Navraj Mattu, Aravind M. Virupaksha, Anup Belludi
| Article suivant Article suivant
  • Effects of miniplate anchored Herbst appliance on skeletal, dental and masticatory structures of the craniomandibular apparatus: A finite element study
  • Isha Duggal, Maninder Singh Sidhu, Anoop Chawla, Ashish Dabas, Vivek Kumar Dhimole

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.