S'abonner

Étude comparative entre les vis à angle fixe et les vis poly-axiales dans la fixation du radius distal avec deux plaques verrouillées palmaires - 04/06/21

Comparative study between fixed-angle and polyaxial screws in distal radius fixation with two volar locking plates

Doi : 10.1016/j.rcot.2020.12.008 
Álvaro Toro-Aguilera a, d, , Pablo Martínez-Galarza a, e, Pilar Camacho-Carrasco b, Miguel Caballero c, Josep M. Segur b
a Department of Orthopaedics and Trauma Surgery, Hospital General de Granollers, Avinguda Francesc Ribas s/n, 08402 Granollers, Espagne 
b Department of Orthopaedic and Trauma Surgery, Hospital Clínic, University of Barcelona, c/de Villarroel, 170, 08036 Barcelona, Espagne 
c Surgery Department Research Registrar, IDIBAPS, University of Barcelona, c/Rosselló, 149-153, 08036 Barcelona, Espagne 
d Department of Orthopaedics and Trauma Surgery, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, c/ Sant Antoni Maria Claret, 167, 08025 Barcelona, Espagne 
e Department of Orthopaedics and Trauma Surgery, Hospital de Mollet, Ronda Pinetons, 6, 08100 Mollet del Vallès, Espagne 

Auteur correspondant. Department of Orthopaedics and Trauma Surgery, Hospital de la Santa Creu i Sant Pau Hospital de la Santa Creu i Sant Pau, c/Sant Antoni Maria Claret, 167, 08025 Barcelona, Espagne.Department of Orthopaedics and Trauma Surgery, Hospital de la Santa Creu i Sant Pau Hospital de la Santa Creu i Sant Pauc/Sant Antoni Maria Claret, 167Barcelona08025Espagne
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 04 June 2021
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Introduction

When treating a distal radius fracture with a volar locking plate (VLP), numerous plate-screw designs are available. To date, there is not a screw fastening system with a clear superiority among the others.

Hypothesis

Fixed-angle screws are superior to polyaxial screws in distal radius VLP fixation with respect to screw protrusion and reduction preservation.

Material and methods

A prospective cohort study based on eighty patients was performed. The first forty patients were treated by polyaxial VLP (PA group) were the next forty by a fixed-angle VLP (FA group). Fixation was performed by the flexor carpi radialis approach. Screws were placed 2mm shorter than actual measurement and intraoperative AP, lateral and tilt wrist views were done routinely. A computed tomography (CT) was conducted searching for screw protrusion. Loss of reduction was calculated from the difference between post-operative X-rays values and those at the 6-month follow-up. The total follow-up was 12 months with no losses.

Results

Postoperative CT detected dorsal screw protrusion in 17 patients in PA group and 16 patients in FA group that intraoperative radiographs were assumed as correct (p=0.48). The mean invasion of dorsal cortex was of 2.2mm (1–7mm) for PA group and 2.6mm (1–5mm) for FA group (p=0.70). As from those protruding screws, the mean size was registered founding that fixed-angle screws had protrusions with shorter screws 20 vs. 22mm (p<0.05). Intraarticular screw protrusion was registered in 3 and 2 patients respectively (p>1.0). Experienced loss of reduction in volar tilt (p=0.42), radial inclination (p=0.75) and ulnar variance (p=0.83) were equivalent in both groups while a better preservation of the radial height in the PA group was observed (p<0.05).

Discussions

In terms of screw protrusion rate, both fastening systems where similar. However, fixed-angle group invaded the dorsal cortex with shorter screws. Polyaxial screws were associated with a better preservation of the radial height. Finally, this study reinforces the idea that dorsal and articular screw protrusion is more frequent than we expected.

Level of evidence

II; therapeutic, prospective cohort study.

Le texte complet de cet article est disponible en PDF.

Keywords : Distal radius fracture, Volar locking plate, Fixed-angle screw, Polyaxial screw, Screw penetration



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.