S'abonner

The effect of reformatting axis of computed tomography scans on the measurement of deformities in scaphoid waist nonunion - 16/06/21

Doi : 10.1016/j.otsr.2021.102980 
Gwan Bum Lee, Jae Kwang Kim, Young Ho Shin
 Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Wednesday 16 June 2021
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

Computed tomography (CT) has been used to understand the deformity of scaphoid nonunion, but no standard protocol for the reformatting of scaphoid CT imaging exists. The purpose of this study was to compare the reliability of measurements of the deformity of scaphoid waist nonunion between CT-scans reformatted in line with the scaphoid long axis and CT-scans reformatted in line with the wrist axis.

Hypothesis

We hypothesized that CT-scan which was reformatted along the scaphoid long axis is more reliable for understanding the deformity of scaphoid waist nonunion.

Patients and methods

CT-scans of 28 wrists with a scaphoid waist nonunion were reformatted along both the long axis of the scaphoid and of the wrist. For each set of CT-scans, the nonunion gap in axial, coronal and sagittal series, the intrascaphoid angle, and the height to length ratio were measured. All scans were reviewed twice by three observers and intraclass correlation coefficients (ICCs) for inter- and intraobserver reliability were assessed.

Results

For the measurement of nonunion gaps and height to length ratio, neither inter- nor intraobserver reliability showed significant differences between the two reformatting scans. However, for the intrascaphoid angle, both inter- (ICC: 0.202 vs. 0.419, p<0.001) and intraobserver (ICC: 0.614 vs. 0.790, p<0.001) reliability were significantly higher on scaphoid axis CT-scan than on wrist axis CT-scan.

Discussion

In the assessment of deformity in patients with scaphoid waist nonunion, scaphoid axis reformatting CT-scans showed superior reliability for the measurement of intrascaphoid angle than did wrist axis reformatting CT-scans. Although there are several limitations for the correct assessment of all three-dimensional deformity, scaphoid axis reformatting CT-scans could help in assessing the extent of humpback deformity in patients with scaphoid waist nonunion.

Level of evidence

IV; diagnostic.

Le texte complet de cet article est disponible en PDF.

Keywords : Scaphoid, Nonunion, Humpback deformity, 3D reformatting CT-scans


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.