S'abonner

Comparison of periprosthetic bone mineral density between two types of short-stems in total hip arthroplasty with a mean follow-up of 4 years - 20/08/21

Doi : 10.1016/j.otsr.2021.103044 
Az-Eddine Djebara , Abdelkader El Yagoubi, Patrice Mertl, Bachar El Fatayri, Massinissa Dehl, Antoine Gabrion
 Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 20 August 2021
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Introduction

The use of short stems in primary hip arthroplasty has grown considerably in recent years, with a large variety of designs and stabilization methods available. Few studies have directly compared how these designs and fixation modes influence the bone mineral density (BMD) that is said to be better preserved with shorter implants. This led us to carry out a medium-term retrospective comparative study to (1) specify how the design of two different types of short stems influences the periprosthetic BMD, (2) compare the radiological and clinical outcomes of these stems.

Hypothesis

The periprosthetic BMD of a short stem varies based on the implant's design.

Materials and methods

Ninety-three patients underwent total hip arthroplasty (THA) with a short stem between July 2012 and July 2014. Two groups of patients were formed: Vitae™ short stem (Adler Ortho, Milan, France), Optimys™ short stem (Mathys, Bettlach, Switzerland). The Vitae group consisted of 46 patients, while the Optimys group consisted of 47 patients. The mean age was 66 years, and the mean body mass index (BMI) was 26 kg/m2. The groups had comparable age, BMI, sex, Harris Hip score and preoperative radiological features. Periprosthetic BMD of the two types of implants was determined between the 1st and 4th year postoperative using dual-energy x-ray absorptiometry (DEXA) in the Gruen zones. The radiological and clinical outcomes were also determined.

Results

There was a significant decrease in BMD in zone 7(−5.8%±0.1 CI95%[−0.09; −0.02] (p=0.003)), zone 2 (−4.8% ±0.1 CI95%[−0.093; −0.003] (p=0.038)) and zone 6 (−11% ±0.2 CI95%[−0.19; −0.03] (p=0.009)) in the patients with Vitae stems and in zone 2 (−13.7%±0.3 CI95%[−0.25; −0.03] (p=0.018)) in the patients with Optimys stems. A significant difference in BMD in zone 7 at 1 year (p=0.014) and 4 years (p=0.001) postoperative and in zone 6 (p=0.011) at 4 years postoperative existed between groups, with the Optimys group having higher BMD. There was a significant increase in femoral offset in the Optimys group but not the Vitae group: Δoffset=–0.50 mm±5.2 CI95%[−2.05; 1.05] (p=0.522) and Δoffset=2.79 mm±4.2 CI95%[1.21; 4.37] (p=0.001). The Harris Hip score was not significantly different between the two groups at 4 years postoperative (95.3±2.5 [88; 99] vs. 95.2±2.6 [88; 99] (p=0.991)).

Discussion

The design of short stems appears to influence the distribution of loads and the periprosthetic BMD. These stems are associated with very good radiological and clinical results in the medium term. Bone remodeling appears to continue beyond 1 year after the THA procedure.

Level of evidence

III; Retrospective case-control study.

Le texte complet de cet article est disponible en PDF.

Keywords : Short stem, Bone remodeling, Gruen zone, Dual-energy X-ray absorptiometry


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.