S'abonner

Accuracy of 3-dimensional soft tissue prediction for orthognathic surgery in a Chinese population - 24/08/21

Doi : 10.1016/j.jormas.2021.08.001 
KER JIA CHERYL LEE a, , SUAT LI TAN b , HUI YIN ADA LOW c , LU JIE CHEN d , CHEE WENG YONG e , MING TAK CHEW f
a National Dental Centre, Level 8, Academic Clinical Program (ACP) Office, 5 Second Hospital Ave, 168938, Singapore 
b National Dental Centre, Singapore, Address: 5 Second Hospital Ave, 168938, Singapore 
c National Dental Centre, Singapore, Address: 5 Second Hospital Ave, 168938, Singapore 
d Singapore University of Technology and Design, Address: 8 Somapah Road, 487372, Singapore 
e National University of Singapore, Address: 21 Lower Kent Ridge Road, 119077, Singapore 
f National Dental Centre, Singapore, Address: 5 Second Hospital Ave, 168938, Singapore 

Corresponding author at: National Dental Centre, Level 8, Academic Clinical Program (ACP) Office, 5 Second Hospital Ave, 168938, Singapore.National Dental CentreLevel 8, Academic Clinical Program (ACP) Office, 5 Second Hospital Ave168938Singapore
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Tuesday 24 August 2021
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Objectives

This study aims to determine the validity of a 3D planning software in predicting the soft tissue outcome of Chinese patients undergoing orthognathic surgery for correction of Skeletal III dentofacial deformity.

Methods

Pre- and post-operative 3D facial stereophotogrammetric scans and cone beam computed tomography were taken for 10 Chinese patients who had underwent orthognathic surgery. The pre-operative 3D facial scan was integrated with the pre-operative CBCT using the ProPlan CMF software. The simulated soft tissue 3D face was then compared with the actual 3D facial scan obtained at least 6 months postoperatively. Two outcome measures were computed as follows (i) mean absolute difference between meshes (ii) percentage of points where the distance between the two meshes is 2mm or less.

Results

The mean absolute difference between the predicted and actual soft tissue surface meshes for the full face and the 6 anatomic regions ranged from 0.72mm to 1.42 mm. The mean absolute distance between the meshes for all the anatomic regions were within 2 mm (p<0.05). The percentage of mesh points with less than 2mm error ranged from 72.5% to 92.5%. The accuracy of soft tissue prediction, assessed using mean absolute distance for the full face, was significantly correlated to the amount of sagittal surgical movement (r=0.707, p=0.022). The lower lip was also found to be the least accurate.

Conclusions

Using ProPlan CMF, the accuracy of 3D soft tissue predictions for bimaxillary orthognathic surgery in Chinese Skeletal III patients were clinically satisfactory.

Le texte complet de cet article est disponible en PDF.

Keywords : Orthognathic surgery, Virtual surgical planning, Simulation, 3D planning, Digital dentistry


Plan


© 2021  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.