S'abonner

Virtual preoperative planning of acetabular fractures using patient-specific biomechanical simulation: A case-control study - 06/10/21

Doi : 10.1016/j.otsr.2021.103004 
Mehdi Boudissa a, b, , Gaëtan Bahl b, Hadrien Oliveri b, Matthieu Chabanas b, Jérôme Tonetti a, b
a Department of Orthopaedic and Trauma Surgery, Grenoble University Hospital, University Grenoble-Alpes, 38700 La-Tronche, France 
b TIMC-IMAG lab, CNRS UMR 5525, University Grenoble-Alpes, 38700 La-Tronche, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

The first patient-specific biomechanical model for planning the surgical reduction of acetabular fractures was developed in our institution and validated retrospectively. There are no prior studies showing its effectiveness in terms of reduction quality, operative duration and intraoperative bleeding. Therefore, we performed a case control study aiming to: 1) evaluate the effect of preoperative simulation by patient-specific biomechanical simulator on the operating time and intraoperative bleeding; 2) evaluate the effect of preoperative simulation by patient-specific biomechanical simulator on the quality of reduction.

Method

All patients operated on between January 2019 and June 2019 after planning by biomechanical simulation were included in this case-control study. Each patient included was matched to 2 controls from our database (2015–2018) according to age and fracture-type. DICOM data were extracted from the preoperative high-resolution scanners to build a three-dimensional model of the fracture by semi-automatic segmentation. A biomechanical model was built to virtually simulate the different stages of surgical reduction. Surgery was then performed according to simulation data. Surgical duration, blood loss, radiological findings and intraoperative complications were recorded, analysed and compared.

Results

Thirty patients were included, 10 in the simulation group and 20 in the control group. The two groups were comparable in terms of age, time from accident to surgery, fracture-type and surgical approach. The mean operative time was significantly reduced in the simulation group: 113min±33 (60–180) versus 196min±32 (60–260) (p=0.01). Mean blood loss was significantly reduced in the simulation group: 505mL±189 (100–750) versus 745mL±130 (200–850) (p<0.01). However, no significant difference was found in the radiological results according to Matta's criteria, although an anatomical reduction was obtained for 9 patients in the simulation group (90%) versus 12 patients in the control group (60%) (p=0.26). A postoperative neurological complication was recorded in the control group (sensory deficit of the lateral cutaneous nerve of thigh).

Conclusion

This study confirms the promising results of preoperative planning in acetabular trauma surgery based on patient-specific biomechanical simulation as well as its feasibility in routine clinical practice. By providing a better understanding of the fracture and its behavior, a reduction in intraoperative bleeding and in operative duration is achieved.

Level of evidence

III; case-control study.

Le texte complet de cet article est disponible en PDF.

Keywords : Acetabular fracture, Biomechanical model, Virtual planning, Computer-assisted surgery, Segmentation


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 107 - N° 6

Article 103004- octobre 2021 Retour au numéro
Article précédent Article précédent
  • Early posttraumatic ankle osteoarthritis following ankle fracture-dislocations in a sub-Saharan African setting
  • Loïc Fonkoue, Lamine Sarr, Kennedy Olivier Muluem, Alioune Badara Gueye, Badara Dembele, Clovis Fon, Olivier Ngongang, Charles Bertin Dieme, André-Daniel Sané
| Article suivant Article suivant
  • Inter- and intraobserver reliability assessment of the 2018 AO/OTA classification for high-energy pelvic ring injuries: A retrospective study
  • Alexandre Ansorge, Michaël de Foy, Antoine Poncet, Axel Gamulin

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.