Les chirurgiens orthopédistes sont-ils soumis à une irradiation oculaire excessive ? Étude prospective de l’irradiation du cristallin en orthopédie-traumatologie? - 12/10/21

Are orthopedic surgeons exposed to excessive eye irradiation? A prospective study of lens irradiation in orthopedics and traumatology

Doi : 10.1016/j.bloc.2021.09.004 
Céline Cuenca a,  : MD, assistante spécialiste, Pierre-Jean Mention b : PH, Guillaume Vergnenègre a : PH, Pierre-Alain Mathieu a : PU-PH, Jean-Louis Charissoux a : PU-PH, Pierre-Sylvain Marcheix a : PH, responsable du SOS main
a Service de chirurgie orthopédique et traumatologique, CHU de Limoges, 2 avenue Martin-Luther-King, 87042 Limoges cedex, France 
b Service de médecine nucléaire, CHU d’Angers,4 rue Larrey, 49933 Angers cedex 9, France 

*Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 2
Vidéos 0
Autres 0

Résumé

Introduction

De nombreuses études réalisées ces dernières années ont mis en avant le risque augmenté de pathologies liées à l’irradiation chez les soignants en rapport avec l’utilisation des rayonnements ionisants z Un décret français a été adopté le 4 juin 2018 divisant par 7,5 la dose limite d’irradiation autorisée au niveau du cristallin pour les travailleurs exposés.

Hypothèse

L’hypothèse de notre travail était de vérifier que l’irradiation oculaire d’un chirurgien orthopédiste restait en dessous de la nouvelle limite légale autorisée.

Méthode

Nous avons relevé, chez 10 orthopédistes (5 seniors et 5 internes), de manière prospective la dose équivalente reçue par le cristallin en mSv grâce à 3 dosimètres passifs placés au niveau du front, et de chaque tempe z Chaque intervention par opérateur a été relevée ainsi que la dose par surface en salle opératoire à chaque utilisation de la scopie.

Résultats

Toutes les doses équivalentes au cristallin relevées par opérateurs à la fin des 4 mois restent bien en deçà des limites autorisées z Les doses relevées au niveau du front ne sont pas significativement différentes des doses relevées au niveau des tempes (p=0,7, p=0,6) z Il n’y a pas non plus de différence en fonction de la latéralité de la tête (p=0,3) z La dose reçue au cristallin est corrélée à la dose émise en salle (p=0,004) z Il n’y a pas de différence significative d’irradiation en fonction de l’expérience du chirurgien (p=0,2) ni en fonction de son taux d’activité de traumatologie (p=0,4).

Discussion

Aucune étude n’a retrouvé de dose équivalente au cristallin supérieure à la limite autorisée z Mais aucune étude n’avait auparavant mesuré les doses équivalentes reçues au cristallin en fonction de l’axe d’arrivée des rayonnements au niveau des yeux z Notre étude montre qu’un orthopédiste reçoit autant de rayonnements oculaires de face que sur les côtés z La radioprotection oculaire doit donc être aussi efficace de face que latéralement z L’expérience du chirurgien dans notre étude n’est pas un facteur protecteur de l’irradiation oculaire.

Le texte complet de cet article est disponible en PDF.

Are orthopedic surgeons exposed to excessive eye irradiation? A prospective study of lens irradiation in orthopedics and traumatology

Introduction. Numerous studies in recent years highlighted an increased risk of pathologies related to ionizing radiation in caregivers. A French decree was adopted on June 4, 2018, dividing by 7.5 the radiation dose authorized in the lens for exposed workers.Hypothesis. The hypothesis of the present study was that ocular irradiation in orthopedic surgeons was below the new legal threshold.Method. The equivalent dose (mSv) received by the lens was prospectively assessed in 10 orthopedic surgeons (5 senior, 5 residents), using 3 passive dosimeters placed at the forehead and either temple. Each intervention of each operator was recorded, with dose per area in the operating room at each use of the fluoroscope.Results. All equivalent doses to the lens at the end of the 4 month study period were well below thresh-old. Doses were not significantly different between forehead and either temple (p = 0.7, p = 0.6 for the 2 temples). There was no difference according to side of the head (p = 0.3). The dose received in the lens is correlated with the dose delivered in the room (p = 0.004). There were no significant differences in irradiation according to the surgeon’s experience (p = 0.2) or trauma activity rate (p = 0.4).Discussion. No studies have reported equivalent doses to the lens exceeding the authorized limit. But none previously measured equivalent dose to the lens according to the axis of irradiation in the eyes. The present study showed that orthopedic surgeons received as much eye radiation laterally as frontally. Ocular radiation protection needs therefore to be as effective laterally as frontally. The surgeon’s experience did not emerge as a protective factor against ocular irradiation.

Le texte complet de cet article est disponible en PDF.

Mots clés : cristallin, irradiation, orthopédie, radioprotection, traumatologie

Keywords : irradiation, lens, orthopedics, radiation protection, traumatology


Plan


 Cet article a fait l’objet d’une première publication dans la Revue de chirurgie orthopédique et de traumatologie. Nous remercions la rédaction en chef, ainsi que les auteurs de nous avoir donné l’autorisation de le republier dans nos pages. DOI de l’article original : https://doi.org/10.1016/j.rcot.2019.02.026.


© 2021  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 40 - N° 3

P. 118-123 - juillet 2021 Retour au numéro
Article précédent Article précédent
  • Exposition des chirurgiens et des patients aux rayonnements ionisants pendant les procédures d’ostéosynthèse rachidienne postérieure percutanée : étude prospective de 100 patients?
  • Pascal Kouyoumdjian, Guillaume Gras Combe, Mickael Grelat, Stéphane Fuentes, Benjamin Blondel, Patrick Tropiano, Fahed Zairi, Jacques Beaurain, Yann-Philippe Charles, Alexandre Dhenin, Hassan Elfertit, Julien Le Roy, Joel Greffier, Nicolas Lonjon
| Article suivant Article suivant
  • Organiser les formations à la radioprotection “travailleur” du personnel de bloc
  • Sophie Cao, Morgane Vittet

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.